Dover Wilden Hornet HU38 Скачать руководство пользователя страница 4

T R O U B L E S H O O T I N G

Pump will not run or runs slowly.

 Ensure air pressure is at least 0.3 bar (5 psig) above start 

1. 

up  pressure  and  differential  pressure  (the  difference 
between air inlet and liquid discharge pressures) is not 
less than 0.7 bar (10 psig).

 Check air inlet filter for debris.  A 5μ (micron) air filter 

2. 

must be installed at the air inlet of the pump to prevent 
air compressor particulate from entering and damaging 
the air distribution system.

 Check  for  air  leakage  (blow  by)  at  the  exhaust  of  the 

3. 

pump.  This could indicate worn seals/bore in the air 
valve.

 Disassemble  pump  and  check  for  obstructions  in  the 

4. 

air passage-ways or objects which would obstruct the 
movement of internal parts.

 Check  for  sticking  check  valves.    If  material  being 

5. 

pumped  is  not  compatible  with  pump  elastomers, 
swelling  may  occur.    Also,  as  the  check  valves  wear, 
they  become  smaller  and  can  become  stuck  in  the 
seats.  

 Diaphragms may have a pinhole allowing air to escape 

6. 

to the liquid side of the pump reducing performance. 

Pump runs but little or no product flows.

 Check for pump cavitation; slow pump speed down to 

1. 

allow thick material to flow into liquid chambers.

 Verify that vacuum required to lift liquid is not greater 

2. 

than the vapor pressure of the material being pumped 
(cavitation).

 Check  for  sticking  check  valves.    If  material  being 

3. 

pumped  is  not  compatible  with  pump  elastomers, 
swelling may occur.  Also, as the check valve wear, they 
become smaller and can become stuck in the seats.  

 Pump  may  be  operating  (cycling)  too  fast.    In  this 

4. 

situation,  to  prime  the  pump  you  must  lower  the  air 
inlet pressure to achieve maximum suction lift.  Once 
pump is primed the inlet air pressure can be raised to 
meet system requirements.

Pump air valve freezes.

 Check  for  excessive  moisture  in  compressed  air 

1. 

line.  Either install a dryer or hot air generator at the 
compressor.    A  coalescing  filter  may  also  be  used  to 
remove the water from the compressed air line some 
applications.

Air bubbles in pump discharge.

Check for ruptured diaphragm.

1. 

 Check  tightness  of  fasteners  and  integrity  of  o-ring  

2. 

and seals.

Ensure hosing connections are airtight.

3. 

Product comes out air exhaust.

Check for diaphragm rupture.

1. 

Each and every product manufactured by Wilden Pump & Engineering, LLC is built to meet the highest standards of quality. 
Every pump is functionally tested to insure integrity of operation.  Wilden Pump & Engineering, LLC warrants that pumps, 
accessories  and  parts  manufactured  or  supplied  by  it  to  be  free  from  defects  in  material  and  workmanship  for  a  period 
of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes  first. Failure due to 
normal wear, misapplication, or abuse is, of course, excluded from this warranty.  Since the use of Wilden pumps and parts is 
beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump & 
Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products 
on any application.  Responsibility is limited solely to replacement or repair of defective Wilden Pump & Engineering, LLC.  All 
decisions as to the cause of failure are the sole determination of Wilden Pump & Engineering, LLC.  Prior approval must be 
obtained from Wilden for return of any items for warranty consideration and must be accompanied by the appropriate MSDS 
for the product(s) involved. A Return Goods Tag, obtained from an authorized Wilden distributor, must be included with the 
items which must be shipped freight prepaid.  The foregoing warranty is exclusive and in lieu of all other warranties expressed 