Dover Wilden Hornet HU38 Скачать руководство пользователя страница 2

   CAUTION:

 Do not apply compressed air or gas to the 

exhaust port – pump will not function.

   CAUTION:

  Do  not  lubricate  air  supply.    Excess 

lubrication will reduce pump performance.  Pump is 
pre-lubed and does not require in-line lubrication.

   TEMpErATUrE LIMITS:

 

Polypropylene  0.0°C to 79.4°C 

(32°F to 175°F)

 

Wil-Flex

TM

 (Santoprene

®

)

 

   

–40.0°C to 107.2°C  (–40.0°F to 225°F)

   CAUTION:

  When  choosing  pump  materials,  check 

the  temperature  limits  for  all  wetted  components.  
Example:  Wil-Flex™ has a maximum limit of 107.2°C 
(225°F)  but  polypropylene  has  a  maximum  limit  of 
only 79.4°C (175°F).

   CAUTION:

  Maximum  temperature  limits  are  based 

upon  mechanical  stress  only.    Certain  chemicals 
will  significantly  reduce  maximum  safe  operating 
temperatures.  Consult Wilden’s Chemical Resistance 
Guide  for  chemical  compatibility  and  temperature 
limits.

   CAUTION:

 Do not exceed 8.6 bar (125 psig) air or gas 

supply pressure.

   CAUTION:

 If used with CO

2

 or N

2

 be sure the area is 

well ventilated.

   WArNING:

  Do  not  pump  gasoline  or  flammable 

liquids or use where flammable vapors are present. 

   CAUTION:

  Process  fluid  and  cleaning  fluids  must 

be  chemically  compatible  with  all  wetted  pump 
components.  Consult Wilden’s Chemical Resistance 
Guide for chemical compatibility.

   CAUTION:

 Always wear safety glasses when operating 

pump.  If diaphragm rupture occurs, material being 
pumped can be forced out air exhaust.

   CAUTION:

 Before removing pump from application, 

the  compressed  air  line  to  the  pump  should  be 
disconnected  and  all  air  pressure  allowed  to  bleed 
from pump.  Disconnect all intake, discharge and air 
lines.  Drain the pump by turning it upside down and 
allowing any fluid to flow into a suitable container.

   NOTE:

 Tighten all hardware prior to installation.  

   NOTE:

 Wilden’s  Hornet™  pump  cannot  be  used  in 

submersible applications.  If your application requires 
a submersible pump, contact your authorized Wilden 
Distributor for an alternative pump model.

C a U T I O N S   –   R E a D   F I R S T !

LEGEND

HU xxx / xxxxx / xxx / xx /xxx/

xxxx

FITTING

O-RINGS

CHECK

VaLVE

SPRING

HORNET

TM

PUMP

CHECK VaLVE

PUMP SIZE 

DIaPHRaGMS

aIR VaLVE

CENTER SECTION

wETTED PaRTS & OUTER PISTON

SPECIaLTy

CODE

(if applicable)

P U M P   D E S I G N a T I O N   S y S T E M

CHECK VaLVE SPRING

H  =  ALLOY C

MaNIFOLD/FITTING O-RING

WF =  WIL-FLEX™ (Santoprene

®

)

aIR VaLVE

E  =  POLYETHYLENE

DIaPHRaGMS/O-RINGS

WBL =   WIL-FLEX™ (Santoprene

®

w/BUNA BACK-UP O-RING,  

IPD (cream)

CHECK VaLVE

WF =  WIL-FLEX™ (Santoprene

®

)

PUMP SIZE

38  =   10 mm (3/8”)  

100  =   13 mm (1/2”)  

wETTED PaRTS & OUTER PISTON

PZ  =  POLYPROPYLENE/NO PISTON

CENTER SECTION

PP  =  POLYPROPYLENE

MaTERIaL CODES

SPECIaLTy CODES

No specialty code - MNPT Connection (note: only available for 10mm (3/8”) at this time)

0645 - Fitting, Hose Barb Connection

Отзывы: