Wilden’s  Hornet™  pump  is  designed  to  meet  the 

performance  requirements  of  even  the  most  demanding 

pumping  applications.    Designed  and  manufactured  to 

the highest standards, this pump is well suited for general 

commercial  and  industrial  applications.    Refer  to  the 

performance  information  in  this  manual  for  an  in-depth 

analysis of the performance of your pump.  

HOSE CONNECTIONS:

  Use flexible suction and discharge 

hose ONLY.  This is done to avoid excess stress on the pump 

port fittings.  The suction hose size should be at least the 

equivalent or larger than the diameter size of the suction inlet 

on your pump.  The suction hose must be non-collapsible, 

reinforced  type  as  these  pumps  are  capable  of  a  high 

vacuum.  Discharge hose should also be the equivalent or 

larger than the diameter of the pump discharge which will 

help to reduce friction losses.  It is critical that all fittings 

and connections are airtight or a reduction or loss of pump 

suction capability will result.  

Final determination of the pump site should not be made 

until  the  piping  challenges  of  each  possible  location 

have  been  evaluated.   The  impact  of  current  and  future 

installations  should  be  considered  ahead  of  time  to 

ensure that inadvertent restrictions are not created for any 

remaining sites.  

INSTALLATION:

    Months  of  careful  planning,  study, 

and  selection  efforts  can  result  in  unsatisfactory  pump 

performance  if  installation  details  are  left  to  chance.  

Premature  failure  and  long  term  dissatisfaction  can  be 

avoided  if  care  is  exercised  throughout  the  installation 

process.

For  best  results,  the  pump  should  use  a  5μ  (micron)  air 

filter, needle valve and regulator.  The use of an air filter will 

ensure that the majority of any pipeline contaminants will 

be eliminated.

Pumps  in  service  with  a  positive  suction  head  are  most 

efficient when inlet pressure is limited to 0.5-0.7 bar (7-10 

psig).  Premature diaphragm failure may occur if positive 

suction is 0.7 bar (10 psig) or higher.

Every pump location should have a gas supply line large 

enough to supply the volume of gas necessary to achieve 

the  desired  pumping  rate.    Use  gas  pressure  up  to  a 

maximum of 8.6 bar (125 psig).

LOCATION:

    Noise,  safety,  and  other  logistical  factors 

usually dictate where equipment will be situated. 

ELEVATION:

  Selecting a site that will be within the pump’s 

dynamic lift capability will assure that loss-of-prime issues 

will  be  eliminated.    In  addition,  pump  efficiency  can  be 

adversely  affected  if  proper  attention  is  not  given  to  site 

location.

ACCESS:

  The location should be accessible.  If it’s easy to 

reach the pump, maintenance personnel will have an easier 

time  doing  routine  inspections  and  adjustments.    Should 

major repairs become necessary, ease of access can play a 

key role in speeding the repair process and reducing total 

downtime.

OpErATION:

    Pump  discharge  rates  can  be  controlled  by 

limiting  the  volume  and/or  pressure  of  the  gas  supply  to 

the  pump  (preferred  method).    An  air  regulator  is  used 

to  regulate  pressure.   A  needle  valve  is  used  to  regulate 

volume.   Pump  discharge  rates can also  be controlled  by 

throttling the pump discharge by partially closing a valve in 

the discharge line of the pump.  This action increases friction 

loss which reduces flow rate.  This is useful when the need 

exists to control the pump from a remote location.  

When  the  pump  discharge  pressure  equals  or  exceeds 

the gas supply pressure, the pump will stop; no bypass or 

pressure  relieve  valve  is  needed,  and  pump  damage  will 

not occur.  The pump can be restarted by reducing the fluid 

discharge  pressure  or  increasing  the  inlet  gas  pressure.  

The Wilden  Hornet™  pump  runs  solely  on  clean-dry  gas 

and  generates  little  heat.   Therefore,  your  process  fluid 

temperature will not be affected.  

SUBMErSIBLE AppLICATIONS:

  The Wilden Hornet™ pump 

design is not suited for submersible applications.

WArNING:

   The  Hornet™  pump  is  intended  for  use  with 

fluids having little or no particulates in the process media.  

Excessive  or  large  particulates  in  the  process  media  will 

adversely affect pump performance and service life.

S U G G E S T E D   I N S T a L L a T I O N

R E P L a C E M E N T   K I T S

Item Description

Qty. Item Number

1

***Kit, Hardware, Hornet 

1

85-6350-99

2

***Kit, Check Valve, Wilflex

1

85-9190-58

3

***Kit, Diaphragm, Wilflex 

1

85-9545-58

4

***Kit, Fitting, 3/8” NPT

1

85-7779-99

4

***Kit, Fitting, 3/8” Barbed

1

85-7780-99

4

***Kit, Fitting, 1/2” Barbed

1

85-7782-99

5

***Kit, Retaining Clips

1

85-7783-99

6

***Kit, Air Fitting, Assembly

1

85-2175-99

*** Item number and price are for individual kits, minimum order quantity is 12. 