WIL-11210-E-15
7
WILDEN PUMP & ENGINEERING, LLC
S e c t i o n 5 A
P E R F O R M A N C E
P400 ALUMINUM
PTFE-FITTED
P400 ALUMINUM
FULL-STROKE PTFE-FITTED
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
Height .................................594 mm (23.4")
Width ..................................343 mm (13.5")
Depth ..................................340 mm (13.4")
Ship Weight .........Aluminum 25 kg (55 lb)
Air Inlet ................................... 13 mm (1/2")
Inlet ......................................38 mm (1-1/2")
Outlet ...................................38 mm (1-1/2")
Suction Lift ......................3.4 m Dry (11.3')
8.9 m Wet (29.5')
Displacement/Stroke .........0.57 L (0.15 gal)
1
Max. Flow Rate ..............329 lpm (87 gpm)
Max. Size Solids .................7.9 mm (5/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example: To pump 114 lpm (30 gpm)
against a discharge pressure head of
2.8 bar (40 psig) requires 3.8 bar
(55 psig) and 46 Nm
3
/h (27 scfm) air
consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Height ................................ 594 mm (23.4”)
Width ..................................343 mm (13.5”)
Depth ................................. 340 mm (13.4”)
Ship Weight .........Aluminum 25 kg (55 lb)
Air Inlet ...................................13 mm (1/2”)
Inlet ..................................... 38 mm (1-1/2”)
Outlet .................................. 38 mm (1-1/2”)
Suction Lift .......................... 5.6 Dry (18.4’)
9.3 m Wet (30.6’)
Disp. Per Stroke ................... 1.1 L (.30 gal)
1
Max. Flow Rate ............ 420 lpm (111 gpm)
Max. Size Solids .................7.9 mm (5/16”)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example: To pump 254 lpm (67 gpm)
against a discharge pressure head of 2.1
bar (30 psig) requires 4.2 bar (60 psig)
and 88.4 Nm
3
/h (55 scfm).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Содержание Wilden Advanced P400
Страница 15: ...PX400 M E T A L P X 4 0 0 P E R F O R M A N C E WIL 11210 T 05 ...
Страница 41: ...N O T E S ...
Страница 52: ...N O T E S ...
Страница 53: ...N O T E S ...
Страница 54: ...N O T E S ...