![Dover WILDEN ACCUFLO A8 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/dover/wilden-accuflo-a8/wilden-accuflo-a8_engineering-operation-and-maintenance_2525059002.webp)
WILDEN PUMP & ENGINEERING CO.
TABLE OF CONTENTS
PAGE #
SECTION #1 — PUMP DESIGNATION SYSTEM
......................................
1
SECTION #2 — HOW IT WORKS (PUMP & AIR SYSTEMS)
.........
2
SECTION #3 — CAUTIONS
.........................................................................................
3
SECTION #4 — DIMENSIONAL DRAWINGS
A.
Model T8 PLASTIC Air-Controlled ......................................................................................
4
B.
Model A8 PLASTIC Accu-Flo™ ..........................................................................................
4
SECTION #5 — PERFORMANCE CURVES
A.
Model T8 PLASTIC Rubber-Fitted......................................................................................
5
B.
Model T8 PLASTIC Ultra-Flex™-Fitted ..............................................................................
5
C.
Model T8 PLASTIC TPE-Fitted...........................................................................................
6
D.
Model T8 PLASTIC Teflon
®
-Fitted.......................................................................................
6
E.
Model A8 PLASTIC Accu-Flo™ Rubber/TPE-Fitted ...........................................................
7
F.
Model A8 PLASTIC Accu-Flo™ Rubber/TPE-Fitted 70/30 Operating Condition................
7
G.
Model A8 PLASTIC Accu-Flo™ Ultra-Flex™/Teflon
®
-Fitted................................................
8
H.
Model A8 PLASTIC Accu-Flo™ Ultra-Flex™/Teflon
®
-Fitted 70/30 Operating Condition ....
8
SECTION #6 — SUCTION LIFT CURVES & DATA
A.
Model T8 PLASTIC Air-Controlled ......................................................................................
9
B.
Model A8 PLASTIC Accu-Flo™ ..........................................................................................
9
SECTION #7 — INSTALLATION & OPERATION
A.
Installation — Air-Controlled Pumps...................................................................................
10
B.
Air-Controlled Operation and Maintenance ........................................................................
11
C.
Accu-Flo™ Operating Principles ........................................................................................
12
D.
Installation — Accu-Flo™ Pumps .......................................................................................
12
E.
Accu-Flo™ Operation and Maintenance ............................................................................
13
F.
Troubleshooting Air-Operated Pumps ................................................................................
14
G.
Troubleshooting Accu-Flo™ Pumps ...................................................................................
14
SECTION #8 — DIRECTIONS FOR DISASSEMBLY/REASSEMBLY
A.
Model T8 PLASTIC Wetted Path — Tools Required, Torque Specs, Cautions..................
15
B.
Turbo-Flo™ Air Valve — Disassembly, Cleaning, Inspection ............................................
18
C.
Reassembly Hints & Tips....................................................................................................
20
D.
Gasket Kit Installation .........................................................................................................
21
SECTION #9 — EXPLODED VIEW/PARTS LISTING
A.
Model T8 PLASTIC Rubber/TPE-Fitted..............................................................................
22
B.
Model T8 PLASTIC Teflon
®
-Fitted.......................................................................................
24
C.
Model A8 PLASTIC Accu-Flo™ ..........................................................................................
26
SECTION #10 — REFERENCE
A.
Elastomer Options ..............................................................................................................
28
B.
Accu-Flo™ Electrical Information .......................................................................................
28
C
l
a
ss
I
&
I
I Ozone
D
ep
le
ting Su
bs
ta
n
c
e
s
NON
USE
U.S. Clean Air Act
Amendments of 1990
Содержание WILDEN ACCUFLO A8
Страница 31: ...WILDEN PUMP ENGINEERING CO 29 MAINTENANCE RECORD DATE SERVICE RENDERED SERVICED BY...
Страница 32: ...30 WILDEN PUMP ENGINEERING CO NOTES...
Страница 33: ...31 WILDEN PUMP ENGINEERING CO NOTES...
Страница 34: ...32 WILDEN PUMP ENGINEERING CO NOTES...
Страница 35: ...WILDEN PUMP ENGINEERING CO...