SECTION 7F – AIR-CONTROLLED

TROUBLESHOOTING

Pump will not run or runs slowly.
1.

Check air inlet screen and air filter for debris.

2.

Check for sticking air valve, flush air valve in solvent.

3.

Check for worn out air valve. If piston face in air valve is

shiny instead of dull, air valve is probably worn beyond working
tolerances and must be replaced.
4.

Check center block Glyd™ rings. If worn excessively, they

will not seal and air will simply flow through pump and out air
exhaust. Use only Wilden Glyd™ rings as they are of special
construction.
5.

Check for rotating piston in air valve.

6.

Check type of lubricant being used. A higher viscosity oil

than suggested may cause the piston to stick or run erratically.
Wilden suggests the use of an oil with arctic characteristics (ISO
15-5 wt.).

Pump runs but little or no product flows.
1.

Check for pump cavitation; slow pump speed down to

match thickness of material being pumped.
2.

Check for sticking ball check valves. If material being

pumped is not compatible with pump elastomers, swelling may

occur. Replace ball check valves and O-rings with the proper
elastomers.
3.

Check to make sure all suction connections are air tight,

especially clamp bands around intake balls.

Pump air valve freezes.
Check for excessive moisture in compressed air. Either install
dryer or hot air generator for compressed air.

Air bubbles in pump discharge.
1.

Check for ruptured diaphragm.

2.

Check tightness of clamp bands, especially at intake mani-

fold.

Product comes out air exhaust.
1.

Check for diaphragm rupture.

2.

Check tightness of piston plates to shaft.

Pump rattles.
1.

Create false discharge head or suction lift.

SECTION 7G – ACCU-FLO™

TROUBLESHOOTING

Pump will not run.
1.

Check for pressurized air at the inlet. (3.1 Bar [Min. 45 psig].)

2.

Check air inlet and filter for debris.

3.

Connect a test lamp to the two wires which run to pump

and ensure that the lamp cycles on and off.
4.

Make sure that the air valve manual override (small red

knob on front of valve) is switched to the “0” position.
5.

Check pilot pressure vent at the top of the operator/coil

assembly to ensure that it is not clogged.
6.

Check for a worn out air valve. If air continually blows out

the exhaust in very large quantities, the air valve seals may be
worn beyond their ability to function. In this case, the valve must
be replaced.
NOTE: Before the valve is scrapped, it is possible that it may be
saved by completely disassembling the valve, cleaning all
components and relubricating the valve.

Pump runs but little or no fluid comes out.
1.

Check that the discharge isolation valve is not closed.

2.

Check that the electronic signal is slow enough that the

pump is able to complete each physical stroke before it is
signaled to change direction. The time required to complete the
stroke is determined by a variety of factors which include fluid
viscosity and head pressure. The shaft can be viewed if the
muffler is removed to verify that the pump is stroking.
3.

Check for pump cavitation; slow pump speed down to

match the thickness of the material being pumped.
4.

Check for sticking ball check valves. If the material being

pumped is not compatible with the pump elastomers, swelling
may occur. Replace ball check valves and O-ring with the
proper elastomers.
5.

Check to make sure that all suction connections are air

tight, and that the clamp bands are properly tightened.

Pump air passages blocked with ice.
Check for excessive moisture in compressed air line. As the
air expands out the exhaust during the operation of the pump,

water vapor entrapped in the compressed air can freeze and
block the air passageways in the pump. If this occurs, it may
be necessary to install a coalescing filter, an air dryer, or a hot
air generator for the compressed air.

Air bubbles in pump discharge.
1.

Check for ruptured diaphragm.

2.

Check tightness of clamp bands, and the integrity of the

O-rings, especially at intake manifold.

Product comes out air exhaust.
1.

Check for diaphragm rupture.

2.

Check tightness of piston plates to shaft.

Pump rattles.
1.

Create false discharge head or suction lift.

Solenoid buzzes or solenoid burnout.
1.

Incorrect voltage, faulty or dirty solenoid.

Solenoid valve fails to shift electrically but shifts with
manual override.
1.

Incorrect voltage, defective coil or wiring.

Solenoid valve fails to shift electrically or with manual
override.

1.

Inadequate air supply, contamination, inadequate or

improper lubrication, mechanical binding in the valve.

Valve shifts but fails to return.

1.

Broken spring, mechanical binding.

Excessive leaking from air valve vent.

1.

Worn seals in air valve.

Содержание WILDEN ACCUFLO A8

Страница 1: ...T8 A8P 2 00 REPLACES EOM T8 A8P 4 99 motralec 4 rue Lavoisier ZA Lavoisier 95223 HERBLAY CEDEX Tel 01 39 97 65 10 Fax 01 39 97 68 48 Demande de prix e mail service commercial motralec com www motralec...

Страница 2: ...el T8 PLASTIC Air Controlled 9 B Model A8 PLASTIC Accu Flo 9 SECTION 7 INSTALLATION OPERATION A Installation Air Controlled Pumps 10 B Air Controlled Operation and Maintenance 11 C Accu Flo Operating...

Страница 3: ...LVE BALL BN BUNA N Red Dot FG SANIFLEX FV FOOD GRADE VITON ND NORDEL Blue NE NEOPRENE Green PU POLYURETHANE TF TEFLON PTFE White VT VITON Silver or White Dot WF WIL FLEX Orange VALVE SEAT O RING BN BU...

Страница 4: ...A reaches the limit of its discharge stroke the air valve redirects pressurized air to the back side of diaphragm B The pressurized air forces diaphragm B away from the center block while pulling diap...

Страница 5: ...essed air line to the pump should be disconnected and all air pressure allowed to bleed from pump Disconnect all intake discharge and air lines Drain the pump by turning it upside down and allowing an...

Страница 6: ...D 3 1 32 RAD S 19 8 DIA 25 32 DIA Tee section is designed to accommodate both standard and metric pipe connections SECTION 4B DIMENSIONAL DRAWING WILDEN MODEL A8 PLASTIC ACCU FLO 0 1 A 1 2 FNPT AIR EX...

Страница 7: ...75 200 225 250 275 300 BAR 0 1 2 3 4 5 6 7 8 GPM l min Discharge Pressure 20 34 40 68 60 102 80 136 100 170 FEET SECTION 5B PERFORMANCE CURVES MODEL T8 PLASTIC ULTRA FLEX FITTED Height 770 0 mm 305 16...

Страница 8: ...300 BAR 0 1 2 3 4 5 6 7 8 GPM lmin Water Discharge Flowrates 76 151 227 303 378 454 530 Discharge Pressure 606 SECTION 5D PERFORMANCE CURVES MODEL T8 PLASTIC TEFLON FITTED Height 770 0 mm 305 16 Widt...

Страница 9: ...air pressures Recommendations for optimal speed can be found on the right side of the flow curve Flow rates indicated on chart were determined by pumping water For optimum life and performance pumps s...

Страница 10: ...n and a pump speed of 120 strokes minute See dot on chart Caution Do not exceed 8 6 Bar 125 psig air supply pressure Flow curves are for optimal speed conditions only The optimal speed is that speed w...

Страница 11: ...tion loss all affect the amount of suction lift your pump will attain SECTION 6B SUCTION LIFT CURVES DATA Suction lift curves are calibrated for pumps operating at 305 m 1 000 above sea level This cha...

Страница 12: ...ted For best results the pumps should use an air filter regulator and lubricator system 3 ELEVATION Selecting a site that is well within the pump s suction lift capability will assure that loss of pri...

Страница 13: ...enance problems and unscheduled downtime In addition accurate records make it possible to identify pumps that are poorly suited to their appli cations MAINTENANCE AND INSPECTIONS Since each applicatio...

Страница 14: ...nufactured with wetted parts of polypropy lene or PVDF The center section of the A8 Plastic pump is of aluminum or polypropylene construction A variety of diaphragms valve balls and O rings are availa...

Страница 15: ...unit runs under extreme conditions continuous operation at high speeds it may be necessary to relubricate the center block with a Buna N compatible NLGI Grade 2 grease every 50 million cycles Continuo...

Страница 16: ...t the exhaust in very large quantities the air valve seals may be worn beyond their ability to function In this case the valve must be replaced NOTE Before the valve is scrapped it is possible that it...

Страница 17: ...8 cm 2 inlet and outlet and is designed for flows up to 590 5 lpm 156 gpm The model T8 plastic is available in polypropylene and PVDF wetted parts The air valve is manufactured of brass Teflon coated...

Страница 18: ...ke manifold to the liquid chambers and lift away the intake mani fold to expose intake valve balls and seats Figure 5 Step 6 Figure 6 Inspect ball guide bushing ball seat and O ring for nicks gouges c...

Страница 19: ...iaphragm assem bly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable perfor mance Step 12 Figure 12 To remove the diaphragm assembly from the...

Страница 20: ...with the ports on the face of the air valve body see below The piston should also appear to be a dull dark gray in color If the piston appears to be a shiny aluminum color the air valve is probably wo...

Страница 21: ...tion 8D page 16 GLYD RING REPLACEMENT When the Glyd rings become worn they will no longer seal and must be replaced Due to the design characteristics of the Glyd rings it is suggested that you use the...

Страница 22: ...mps Air Valve 6 8 m N 60 in lbs Outer Piston Teflon fitted 78 6 m N 58 ft lbs Outer Piston Rubber fitted 78 6 m N 58 ft lbs Small Clamp Band All 6 2 m N 55 in lbs Medium Clamp Band 10 2 m N 90 in lbs...

Страница 23: ...ene pumps come stan dard with expanded Teflon Gasket Kits P N 08 9501 99 for PVDF and 08 9500 99 for polypropylene Carefully prepare seal ing surfaces by removing all debris and foreign matter from di...

Страница 24: ...x Assembly 18 45 31 19 25 24 36 35 35 8 2 23 14 15 17 13 1 1 12 10 11 21 20 31 19 37 28 33 39 29 34 43 40 38 26 30 27 42 41 16 18 7 4 3 9 Standard Assembly A B C A B 20 SECTION 9A EXPLODED VIEW PARTS...

Страница 25: ...Sunk 2 08 3650 01 08 3650 03 08 3650 02 08 3650 05 08 3650 01 08 3650 03 08 3650 02 08 3650 05 22 Air Chamber Screw 3 8 16 x 39 16 3 08 6200 08 08 6200 03 08 6200 08 08 6200 03 08 6200 08 08 6200 03 0...

Страница 26: ...P ENGINEERING CO 25 24 36 35 35 8 2 23 14 15 17 13 1 1 12 10 11 21 20 31 19 37 28 33 39 29 34 43 40 38 26 30 27 42 41 16 18 7 4 3 9 A B A B 32 SECTION 9B EXPLODED VIEW PARTS LISTING T8 PLASTIC CHAMP T...

Страница 27: ...08 6550 03 24 Liquid Chamber 2 08 5000 20 08 5000 20 08 5000 20 08 5000 20 08 5000 21 08 5000 21 08 5000 21 08 5000 21 25 Discharge Elbow 2 08 5230 20 08 5230 20 08 5230 20 08 5230 20 08 5230 21 08 5...

Страница 28: ...ING CO Ultra Flex Assembly 10 23 11 17 16 28 27 27 23 7 17 1 13 12 23 11 29 20 25 31 21 26 25 32 30 18 22 19 24 33 8 10 Standard Assembly B A B 12 A 2 3 4 38 37 38 SECTION 9C EXPLODED VIEW PARTS LISTI...

Страница 29: ...8 5230 21 08 5230 21 18 Inlet Elbow 2 08 5220 20 08 5220 20 08 5220 21 08 5220 21 08 5220 20 08 5220 20 08 5220 21 08 5220 21 19 Manifold T Section 2 08 5160 20 08 5160 20 08 5160 21 08 5160 21 08 516...

Страница 30: ...A NOTES Teflon encapsulated Viton O rings P N 08 1200 60 500 and P N 08 1300 60 500 are standard on all Teflon fitted pumps Teflon diaphragm P N 08 1010 55 must be used with Neoprene back up diaphrag...

Страница 31: ...WILDEN PUMP ENGINEERING CO 29 MAINTENANCE RECORD DATE SERVICE RENDERED SERVICED BY...

Страница 32: ...30 WILDEN PUMP ENGINEERING CO NOTES...

Страница 33: ...31 WILDEN PUMP ENGINEERING CO NOTES...

Страница 34: ...32 WILDEN PUMP ENGINEERING CO NOTES...

Страница 35: ...WILDEN PUMP ENGINEERING CO...

Страница 36: ...Teflon PFA Aluminum 316 S S Cast Iron Hastelloy FDA USDA 3A Teflon PFA Teflon PTFE SPCI FCSI Drum Pump Kits Wil Gard Equalizers APV Accessories Accessories PRINTED IN THE U S A motralec 4 rue Lavoisi...

Отзывы: