![Dover Unified Brands Randell PH120F Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/dover/unified-brands-randell-ph120f/unified-brands-randell-ph120f_operators-manual_2524824021.webp)
unifiedbrands.net
19
Trouble Shooting Guide
SYMPTOM
POSSIBLE CAUSE
PROCEDURE
Unit doesn’t run
1. No power to unit
1. Plug in unit
2. Temperature control turned off
2. Check temperature control
3. Temperature control faulty
3. Test temperature control
4. Compressor overheated
4. Clean condenser coil
5. Condenser fan faulty
5. Service condenser fan
6. Overload protector faulty
6. Test overload
7. Compressor relay faulty
7. Test relay
8. Compressor faulty
8. Call ASA for service
Unit short cycles
1. Condenser coil dirty
1. Clean coil
2. Service fan and motor.
3. Call ASA for service
4. Check outlet voltage
5. 30 cut in / 20 diff.
2. Condenser fan faulty
3. Compressor faulty
4. Overload repeatedly tripping
5. Pressure control settings
Unit runs constantly
1. Condenser coil dirty
1. Clean coil
2. Condenser fan faulty
2. Service condenser motor
Unit not cold enough
1. Temperature control set too
high
1. Adjust control to lower setting
2. Test control
3. Clean coil
4. Call ASA for service
2. Temperature control faulty
3. Condenser coil dirty
4. Refrigerant leaking or
contaminated
Unit too cold
1. Temperature control set too low
1. Adjust control to raise setting
2. Temperature control faulty
2. Test control
Unit noisy
1. Compressor mountings loose or
hardened.
2. Condenser fan damaged or
hitting fan shroud
1. Tighten or replace compressor
mountings
2. Inspect condenser fan
Dixell control error
1. Sensing probes not making
solid connection
2. P1 or P2
1. Check terminal connections
where probes attach
2. Check probes
Rail coils frozen
1. Defrost probe in position
2.Evaporator fans
3. Air gaps
1. Probe to be in fins of left front
coil
2. Check 5 rail fans for operation
3. Assure all access panels are in
proper position
Содержание Unified Brands Randell PH120F
Страница 2: ......
Страница 4: ......
Страница 17: ...unifiedbrands net 15 Figure A Figure B Figure C Figure D Figure E Figure F Figure G Figure H ...
Страница 20: ...18 888 994 7636 Electrical Diagram ...
Страница 22: ...20 888 994 7636 Replacement Parts Pizza Hut Maketable PH120F PH96F Unit Exterior ...
Страница 23: ...unifiedbrands net 21 Replacement Parts Pizza Hut Maketable PH120F PH96F Refrigerated Rail Top Section ...
Страница 24: ...22 888 994 7636 Replacement Parts Pizza Hut Maketable PH120F PH96F Condensing Unit Door and Shelf Components ...
Страница 25: ...unifiedbrands net 23 Replacement Parts Pizza Hut Maketable PH120F PH96F Coil Assembly ...