Unit Installation (con’t.)
ELECTRICAL SUPPLY: The wiring should be done by a qualified electrician in
accordance with local electrical codes. A properly wired and grounded outlet will
assure proper operation. Please consult the data tag attached to the compressor
to ascertain the correct electrical requirements. Supply voltage and amperage
requirements are located on the serial number tag located inside the mechanical
housing.
NOTE: It is important that a voltage reading be made at the compressor
motor electrical connections, while the unit is in operation to verify the
correct voltage required by the compressor is being supplied. Low or high
voltage can detrimentally affect operation and thereby void its warranty.
NOTE: it is important that your unit has its own dedicated line. Condensing
units are designed to operate with a voltage fluctuation of plus or minus 10%
of the voltage indicated on the unit data tag. Burn out of a condensing unit
due to exceeding voltage limits will void the warranty.
Содержание Unified Brands Randell PH120F
Страница 2: ......
Страница 4: ......
Страница 17: ...unifiedbrands net 15 Figure A Figure B Figure C Figure D Figure E Figure F Figure G Figure H ...
Страница 20: ...18 888 994 7636 Electrical Diagram ...
Страница 22: ...20 888 994 7636 Replacement Parts Pizza Hut Maketable PH120F PH96F Unit Exterior ...
Страница 23: ...unifiedbrands net 21 Replacement Parts Pizza Hut Maketable PH120F PH96F Refrigerated Rail Top Section ...
Страница 24: ...22 888 994 7636 Replacement Parts Pizza Hut Maketable PH120F PH96F Condensing Unit Door and Shelf Components ...
Страница 25: ...unifiedbrands net 23 Replacement Parts Pizza Hut Maketable PH120F PH96F Coil Assembly ...