Dover PSG WILDEN SANIFLO PS2 Series Скачать руководство пользователя страница 5

 

WIL-12330-E-08

 

Wilden

® 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

MATERIAL CODES

 

MODEL 

PS2 = 25 mm (1") 

XPS2 = 25 mm (1") ATE 

WETTED PATH 

S = STAINLESS STEEL

 

OUTER PISTON  

S = STAINLESS STEEL

 

Z = NO PISTON

 

CENTER SECTION 

NN = NICKEL-PLATED  

ALUMINUM 

AIR VALVE 

N = NICKEL-PLATED  

ALUMINUM 

 

DIAPHRAGMS 

FBS = SANITARY BUNA 

1,4

 

(Two Yellow Dots) 

FES = SANITARY EPDM 

1,4

 

(Two Blue Dots) 

FSL = FULL-STROKE SANITARY 

SANIFLEX™ IPD 

1,3,4

 

[Hytrel

®

 (Cream)] 

FSS = SANIFLEX™

1

  

FWL = FULL-STROKE SANITARY  

WILFLEX™, IPD

1,3 

 

[Santoprene

® 

(Two Black Dots)] 

FWS = FULL-STROKE SANITARY  

WIL-FLEX

TM1

 [Santoprene

®

 

(Two Black Dots)] 

LEL = PTFE-EPDM BACKED 

LAMINATE IPD 

1,2,3,4

 

TEU = PTFE w/EPDM 

BACKUP 

1,2,4

 

TSU = PTFE w/SANIFLEX™ 

BACKUP 

1,2,4

  

TSS = FULL-STROKE PTFE  

W/SANIFLEX™  

BACK-UP

1,2,4

 

TWS = FULL-STROKE PTFE  

W/WIL-FLEX™ BACK-UP 

1,2

 

 

BALL VALVES 

FB = SANITARY BUNA 

1,3,4

  

(Red Dot)

 

FE = SANITARY EPDM 

1,3,4

  

(Green Dot) 

FS = SANIFLEX™ 

1,3,4

 

TF = PTFE 

1,2,3,4

 

GASKETS  

FB = SANITARY BUNA-N 

1,3,4

 

(Red Dot) 

FE = SANITARY EPDM 

1,3,4

 

(Green Dot) 

FV = SANITARY FKM 

1,3,4

 

(One White/One 

Yellow Dot) 

TF = PTFE 

1,2,3,4

 

 

NOTES

1

 Meets Requirements of FDA CFR21.177 

2

 Meets Requirements of USP Class VI 

3

 Required for 3-A Certification 

4

 Meets Requirements of 1935/2004/EC

 
 
 
 

 
 
 
 
 

 

NOTE:

 Most Elastomeric materials use colored dots for identification. 

Hytrel

®

 is a registered trademark of DuPont Dow Elastomers.

 

NOTE:

 Not all models are available with all material options.    

Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 

PS2 SANIFLO™ 

HYGIENIC SERIES

 

25 mm (1") Pump 

Maximum Flow Rate:  

121 lpm (32 gpm)

 

 

XPS2  /   X   X   X   X  / XXX / XX /   XX  / 

XXXX 

 

                 

  

    

   

 

                 

  

 

   

MODEL 

                 

  

 

SPECIALTY CODE 

 

                 

 

GASKETS

 

(if applicable) 

 

               

BALL VALVES

   

 

 

         

 

DIAPHRAGMS 

   

     

    

 

         

AIR VALVE

 

 

     

 

   

 

      

  CENTER SECTION 

   

     

 

   

 

 

     OUTER PISTON 

     

 

   

 

 

  WETTED PATH 

     

 

   

 

 

  Section 2 

W I L D E N   P U M P   D E S I G N A T I O N   S Y S T E M

 

SPECIALTY CODES

 

 

 

0770

 

Saniflo HS 

0770E 

Saniflo HS (1935/2004/EC) 

0771

 

Saniflo HS, w/Swivel Stand 

0771E 

Saniflo HS, w/Swivel Stand (1935/2004/EC) 

0772

 

Saniflo HS, Wil-Gard 110V 

0772E 

Saniflo HS, Wil-Gard 110V (1935/2004/EC) 

0773

 

Saniflo HS, Wil-Gard 220V 

0773E 

Saniflo HS, Wil-Gard 220V (1935/2004/EC) 

0774

 

Saniflo HS, Wil-Gard 110V w/Swivel Stand (Required for 3-A cert.) 

0774E 

Saniflo HS, Wil-Gard 110V w/Swivel Stand, Required for 3-A cert. (1935/2004/EC) 

0775

 

Saniflo HS, Wil-Gard 220V w/Swivel Stand (Required for 3-A cert.) 

0775E 

Saniflo HS, Wil-Gard 220V w/Swivel Stand, Required for 3-A cert. (1935/2004/EC) 

0778

 

Saniflo HS DIN Connection 

0778E 

Saniflo HS, DIN Connection (1935/2004/EC) 

0779

 

Saniflo HS, w/Swivel Stand DIN Connection 

0779E 

Saniflo HS, w/Swivel Stand DIN Connection (1935/2004/EC) 

0780

 

Saniflo HS, Wil-Gard 110V DIN Connection 

0780E 

Saniflo HS, Wil-Gard 110V DIN Connection (1935/2004/EC) 

0781

 

Saniflo HS, Wil-Gard 220V DIN Connection 

0781E 

Saniflo HS, Wil-Gard 220V DIN Connection (1935/2004/EC) 

0782

 

Saniflo HS, Wil-Gard 110V w/Swivel Stand DIN Connection 

0782E 

Saniflo HS, Wil-Gard 110V w/Swivel Stand DIN Connection (1935/2004/EC) 

0783

 

Saniflo HS, Wil-Gard 220V w/Swivel Stand DIN Connection 

0783E 

Saniflo HS, Wil-Gard 220V w/Swivel Stand DIN Connection (1935/2004/EC) 

0784

 

Saniflo HS SMS Connection 

0784E 

Saniflo HS, SMS Connection (1935/2004/EC) 

0785

 

Saniflo HS, w/Swivel Stand SMS Connection 

0785E 

Saniflo HS, w/Swivel Stand SMS Connection (1935/2004/EC) 

0786

 

Saniflo HS, Wil-Gard 110V SMS Connection 

0786E 

Saniflo HS, Wil-Gard 110V SMS Connection (1935/2004/EC) 

0787

 

Saniflo HS, Wil-Gard 220V SMS Connection 

0787E 

Saniflo HS, Wil-Gard 220V SMS Connection (1935/2004/EC) 

0788

 

Saniflo HS, Wil-Gard 110V w/Swivel Stand SMS Connection 

0788E 

Saniflo HS, Wil-Gard 110V w/Swivel Stand SMS Connection (1935/2004/EC) 

0789

 

Saniflo HS, Wil-Gard 220V w/Swivel Stand SMS Connection 

0789E 

Saniflo HS, Wil-Gard 220V w/Swivel Stand SMS Connection (1935/2004/EC) 

 

Содержание PSG WILDEN SANIFLO PS2 Series

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE PS2 Saniflo Hygienic Series Metal Pumps WIL 12330 E 08 Where InnovationFlows ...

Страница 2: ...oke TPE Fitted 9 PS2 Saniflo HS Full Stroke PTFE Fitted 9 Suction Lift Curves 10 Section 6 Suggested Installation Operation 11 Maintenance and Troubleshooting Section 7 Disassembly Reassembly 14 Pump Disassembly 14 Wil Gard Diaphragm Sensor 17 Swivel Pump Stand Option 18 Air Valve Center Section Disassembly 19 Single Point Exhaust 22 Reassembly Hints Tips 22 Section 8 Clean In Place CIP 24 Section...

Страница 3: ...lifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written perm...

Страница 4: ...ainers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION The process fluid and cleaning fluids must be chemically compatible with all wetted pump components Consult Chemical Resistance Guide CAUTION Do not exceed 82 C 180 F air inlet temperature for ...

Страница 5: ...ALTY CODES 0770 Saniflo HS 0770E Saniflo HS 1935 2004 EC 0771 Saniflo HS w Swivel Stand 0771E Saniflo HS w Swivel Stand 1935 2004 EC 0772 Saniflo HS Wil Gard 110V 0772E Saniflo HS Wil Gard 110V 1935 2004 EC 0773 Saniflo HS Wil Gard 220V 0773E Saniflo HS Wil Gard 220V 1935 2004 EC 0774 SanifloHS Wil Gard110Vw SwivelStand Requiredfor3 Acert 0774E Saniflo HS Wil Gard 110V w Swivel Stand Required for ...

Страница 6: ...oped in the liquid chamber and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the ...

Страница 7: ...4 E 775 30 5 F 61 2 4 G 505 19 9 H 104 4 1 J 480 18 9 K 648 25 5 L 351 13 8 M 401 15 8 N 394 15 5 P 432 17 0 R ø10 ø 4 LW0436 Rev A DIMENSIONS ITEM METRIC mm STANDARD inch A 343 13 5 B 81 3 2 C 327 12 9 D 540 21 3 E 591 23 3 F 61 2 4 G 322 12 7 H 69 2 7 J 292 11 5 K 460 18 1 L 185 7 3 M 224 8 8 N 191 7 5 P 229 9 0 R ø10 ø0 4 LW0435 Rev A DIMENSIONAL DRAWING Section 4 ...

Страница 8: ...cified so that daily operation parameters will fall in the center of the pump s performance curve PS2 SANIFLO HS FULL STROKE TPE INTEGRAL PISTON DIAPHRAGM FITTED ShipWeight 40 kg 80 lb Air Inlet 1 2 Inlet 25 mm 1 Outlet 25 mm 1 Suction Lift 2 4 m Dry 8 7 9 m Wet 26 Disp Per Stroke1 0 2 L 0 07 gal Max Flow Rate 117 lpm 31 gpm Max Size Solids 6 4 mm 1 4 1 Displacement per stroke was calculated at 4 ...

Страница 9: ... pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve PS2 SANIFLO HS FULL STROKE PTFE FITTED ShipWeight 40 kg 80 lb Air Inlet 1 2 Inlet 25 mm 1 Outlet 25 mm 1 Suction Lift 1 5 m Dry 10 7 6 m Wet 25 Disp Per Stroke1 0 22 L 0 06 gal Max Flow Rate 117 lpm 31 gpm Max Size Solids 6 4 mm 1 4 1 Displacement per stroke was calculated at 4 8 b...

Страница 10: ...00 above sea level This chart is meant to be a guide only There are many variables which can affect the pump s operating characteristics Suction lift can be affected by the number of intake discharge elbow viscosity of pumping fluid elevation atmospheric pressure pipe friction losses and other factors Caution Do not exceed 8 6 bar 125 psig air supply pressure ...

Страница 11: ...ir between the valve and the pump to bleed off which improves pump performance You can estimate pumping volume by counting the number of strokes per minute and then multiplying that figure by the displacement per stroke Muffler Sound levels are reduced below OSHA specifications using the standard Wilden muffler Other mufflers can be used to further reduce sound levels but they usually reduce pump ...

Страница 12: ...oftheair supplytothepump Anair regulator isusedto regulate air pressure A needle valve is used to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance onpage8 Thisisuseful whentheneedexists to control the pump from a remot...

Страница 13: ...s 7 Check for any broken inner piston that would cause the air valve spool to be unable to shift Pump runs but little or no product flows 1 Check for pumpcavitation Slowpumpspeeddownto allow thick materialtoflowintoliquidchambers 2 Verifythatvacuumrequiredtoliftliquidisnotgreater thanthe vaporpressureofthematerialbeingpumped cavitation 3 Check for stickingballcheck valves a Ifmaterialbeingpumpedis...

Страница 14: ...ke discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE The model photographed for these instructions incorporates PTFE diaphragms Step 1 Prior to assembly alignment marks should be placed on the liquid chambers and air chambers to assist with proper alignm...

Страница 15: ... housing to the liquid chamber Step 8 Next remove the ball valve housing valve ball and gasket from liquid chamber To ensure proper alignment during reassembly of manifold liquid chamber interface turn off set portion of valve housing to the left or to the right This procedure works for the inlet manifold and discharge manifold connections Step 9 Now the large clamp bands can be removed NOTE Prior...

Страница 16: ... in the opposite direction loosen and remove one of the two outer pistons Step 11B If your pump is fitted with an IPD the procedure for removing the diaphragm is slightly different In this case simply grasp the diaphragm in two locations and turn in a counterclockwise direction Step 12A After loosening and removing the outer piston the remaining diaphragm assembly and shaft can be removed from the...

Страница 17: ...e primary diaphragm and the back up diaphragm on both sides of the pump at the six o clock position They should be positioned approximately half the distance to the shaft from the edge of the diaphragm Step 2 Prior to installing the liquid chamber and after positioning the Wil Gard sensor cable between the primary and back up diaphragms run the sensor cable along the diaphragm bead but outside the...

Страница 18: ...commended that the pump be disassembled while attached to the stand If it is necessary to remove the pump from the stand while fully assembled use a hoist or mechanical means to support the pump as it is removed from the stand To remove your Saniflo HS pump from the swivel pump stand first loosen the anti rotation bolt item 1 by turning counter clockwise Next ensure the entire pump weight is suppo...

Страница 19: ...s Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container Be aware of hazardous effects of contact with your process fluid NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Using a 9 16 wrench loosen the bolts that connect the center section to the stand CAUTION With bolts removed the center section is no longer attached to ...

Страница 20: ...X air valve incorporates an end cap at both ends of the air valve Step 7 Remove the air valve spool from the air valve body by threading one air valve bolt into the end of the air valve spool and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace entire assembly if necessary Use caution when handling air valve spool to prevent damaging seals NOTE Seals s...

Страница 21: ...pool from pilot spool sleeve and inspect for nicks gouges and wear Replace pilot sleeve or outer sleeve O rings if necessary During reassembly never insert the pilot spool into the sleeve with the notched end first this end incorporates the urethane O ring and will be damaged as it slides over the ports cut in the sleeve NOTE Seals should not be removed from pilot spool Seals are not sold separate...

Страница 22: ... bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section Stainless bolts...

Страница 23: ... easier 5 With the seal clamped in the pliers insert the seal into the bushing bore and position the bottom of the seal into the correct groove Once the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After the pliers are removed you will notice a slight bump in the seal shape Before the sea...

Страница 24: ...causing premature diaphragm failure The following are some details to consider when cleaning the Saniflo HS pump Through the EHEDG certification process the Saniflo HS pump has been validated to clean equivalent to the inlet tubing of the same diameter The cleaning chemical supplier should be consulted and advised of this for their chemical solution and application The same guideline for duration ...

Страница 25: ...WIL 12330 E 08 Wilden 25 EXPLODED VIEW AND PARTS LISTING PS2 SANIFLO HS EXPLODED VIEW Section 9 ...

Страница 26: ...G SMS 2 02 5160 10 387P N A 21 Clamp Band Assy Small 4 02 7100 03 85 22 Clamp Band Assy Large3 2 02 7300 03 385 23 Bolt RHSN 5 16 18 X 2 4 08 6050 03 500 24 Washer 344 I D X 688 O D X 065 THK 4 02 6731 03 25 Wing Nut Medium Clamp 4 08 6661 10 Gaskets Valve Balls 26 Gasket 1 4 27 Gasket 2 8 28 Valve Ball 4 Check Valve Components 29 Ball Cage 1 EHEDG 4 02 5350 10 385P Full Stroke Rubber TPE PTFE FSI...

Страница 27: ...nts 42 Pump Stand Swivel Assy 5 3 A 1 04 7655 03 43 Bushing Center Block Mounting 1 15 7665 03 44 Locking Pin 1 08 7694 03 45 Screw HHC 1 2 13 X 6 1 15 6143 03 41 Screw HHC 3 8 16 X 1 1 4 2 04 6190 03 38 Nut Cap 5 16 18 Pump Stand 4 08 6600 03 72 46 Pad Pump Stand 2 3 A 4 08 7672 20 Accessory Components 47 Control Module Wil Gard II 110 3 A 1 65 8001 99 48 Sensor Cables Wil Gard II 3 A 1 65 8020 9...

Страница 28: ...WIL 12330 E 08 Wilden 28 PS2 SANIFLO HS 1935 2004 EC EXPLODED VIEW EXPLODED VIEW AND PARTS LISTING ...

Страница 29: ...P N A 21 Clamp Band Assy Small 4 02 7100 03 85 22 Clamp Band Assy Large3 2 02 7300 03 385 23 Bolt RHSN 5 16 18 X 2 4 08 6050 03 500 24 Washer 344 I D X 688 O D X 065 THK 4 02 6731 03 25 Wing Nut Medium Clamp 4 08 6661 10 Gaskets Valve Balls 26 Gasket 1 Pkg 4 1 27 Gasket 2 Pkg 2 4 28 Valve Ball Pkg 4 1 Check Valve Components 29 Ball Cage 1 EHEDG 4 02 5350 10 385P Full Stroke Rubber TPE PTFE FSIPD C...

Страница 30: ...nd Components 42 Pump Stand Swivel Assy 5 3 A 1 04 7655 03 43 Bushing Center Block Mounting 1 15 7665 03 44 Locking Pin 1 08 7694 03 45 Screw HHC 1 2 13 X 6 1 15 6143 03 41 Screw HHC 3 8 16 X 1 1 4 2 04 6190 03 38 Nut Cap 5 16 18 Pump Stand 4 08 6600 03 72 46 Pad Pump Stand 2 3 A 4 08 7672 20 Accessory Components 47 Control Module Wil Gard II 110 3 A 1 65 8001 99 48 Sensor Cables Wil Gard II 3 A 1...

Страница 31: ...57 02 1031 57 N A 02 1086 57 N A N A FDA FKM N A N A N A N A N A N A 02 1320 68 85 02 1400 68 85 Product Contact Components LW0438 Rev B PS2 SANIFLOTM HS 1935 2004 EC Material Diaphragms 2 Full Stroke Diaphragms 2 Full Stroke Back Up Diaphragms 2 Full Stroke IPD Diaphragms 2 Full Stroke IPD Back Up Diaphragms 2 Valve Balls 4 Gaskets 1 4 Gaskets 2 8 FDA Buna N 02 1010 69E N A N A N A N A 02 1086 69...

Страница 32: ...WIL 12330 E 08 Wilden ...

Страница 33: ...WIL 12330 E 08 Wilden ...

Страница 34: ...WIL 12330 E 08 Wilden Notes ...

Страница 35: ...WIL 12330 E 08 Wilden Notes Notes ...

Страница 36: ...d Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document 05 2018 ...

Отзывы: