WIL-12330-E-08
Wilden
®
19
Disassembly / Reassembly
Air Valve / Center Section Disassembly
Tools Required:
•
3/16" Hex-Head Wrench
•
Snap-Ring Pliers
•
O-Ring Pick
•
9/16" Wrench
CAUTION:
Before any maintenance or repair is attempted, the compressed air line to the pump should
be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge
and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable
container. Be aware of hazardous effects of contact with your process fluid.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Using a 9/16" wrench, loosen the bolts
that connect the center section to the
stand.
CAUTION:
With bolts removed,
the center section is no longer
attached to the stand and must
be supported so that it does not
fall from the stand.
Step 2
Remove the center section from the
stand.
Step 3
Using a 3/16” hex wrench, loosen air valve
bolts.
.
.