![Dover PSG Wilden PRO-FLO P4 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dover/psg-wilden-pro-flo-p4-series/psg-wilden-pro-flo-p4-series_engineering-operation-and-maintenance_2525041008.webp)
WIL-10183-E-03
Wilden
®
8
PERFORMANCE
P4 METAL
RUBBER-FITTED
Ship Weight ........ Aluminum 13 kg (29 lb)
316 Stainless Steel 20 kg (45 lb)
Cast Iron 22 kg (49 lb)
Alloy C 23 kg (51 lb)
Air Inlet.................................. 19 mm (3/4")
Inlet .................................. 38 mm (1-1/2")
Outlet ................................. 32 mm (1-1/4")
Suction Lift ....................5.8 m Dry (19.0')
8.0 m Wet (26.0')
Disp. Per Stroke
1
.............. 0.98 L (0.26 gal)
Max. Flow Rate ............ 288 lpm (76 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 102 lpm (27 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 22 Nm
3
/h (13 scfm) air consumption
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
P4 METAL
TPE-FITTED
Ship Weight ........ Aluminum 13 kg (29 lb)
316 Stainless Steel 20 kg (45 lb)
Cast Iron 22 kg (49 lb)
Alloy C 23 kg (51 lb)
Air Inlet.................................. 19 mm (3/4")
Inlet .................................. 38 mm (1-1/2")
Outlet ................................. 32 mm (1-1/4")
Suction Lift ................... 5.2 m Dry (17.0')
8.8 m Wet (29.0')
Disp. Per Stroke
1
................ 1.1 L (0.29 gal)
Max. Flow Rate ............ 307 lpm (81 gpm)
Max. Size Solids ................. 4.8 mm (3/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 114 lpm (30 gpm)
against a discharge pressure head of
2.7 bar (40 psig) requires 4.1 bar (60 psig)
and 26 Nm
3
/h (15 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Section 5
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.