WIL-10183-E-03

 

Wilden

®

 

 

 

The Wilden diaphragm pump is an air-operated, placement, self-priming pump. These drawings show the flow pattern  
through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke. 

 

 

 

FIGURE 1 

The air valve directs pressurized 

air  to  the  back  side  of  diaphragm  A.  The 
compressed  air  is  applied  directly  to  the 
liquid  column  separated  by  elastomeric 
diaphragms.  The  diaphragm  acts  as  a 
separation 

membrane 

between 

the 

compressed  air  and  liquid,  balancing  the 
load and removing mechanical stress from 
the diaphragm. The compressed air moves 
the diaphragm away from the center block 
of  the  pump.  The  opposite  diaphragm  is 
pulled  in  by  the  shaft  connected  to  the 
pressurized diaphragm. Diaphragm B is on 
its suction stroke; air behind the diaphragm 
has  been  forced  out  to  the  atmosphere 
through the exhaust port of the pump. The 
movement  of  diaphragm  B  toward  the 
center block of the pump creates a vacuum 
within  chamber  B.  Atmospheric  pressure 
forces  fluid  into  the  inlet  manifold  forcing 
the inlet valve ball off its seat. Liquid is free 
to move past the inlet valve ball and fill the 
liquid chamber (see shaded area). 

FIGURE 

When 

the 

pressurized 

diaphragm, diaphragm A, reaches the limit 
of  its  discharge  stroke,  the  air  valve 
redirects pressurized air to the back side of 
diaphragm  B.  The  pressurized  air  forces 
diaphragm  B  away  from  the  center  block 
while  pulling  diaphragm  A  to  the  center 
block. Diaphragm B is now on its discharge 
stroke. Diaphragm  B forces the inlet  valve 
ball onto its seat due to the hydraulic forces 
developed in the liquid chamber and mani- 
fold  of  the  pump.  These  same  hydraulic   
forces  lift  the  discharge  valve  ball  off  its 
seat,  while  the  opposite  discharge  valve 
ball  is  forced  onto  its  seat,  forcing  fluid  to 
flow  through  the  pump  discharge.  The 
movement  of  diaphragm  A  toward  the 
center block of the pump creates a vacuum 
within  liquid  chamber  A.  Atmospheric 
pressure forces fluid into the inlet manifold 
of  the  pump.  The  inlet  valve  ball  is  forced 
off its seat allowing the fluid being pumped 
to fill the liquid chamber.

 

FIGURE 3 

At completion of the stroke, the 

air  valve  again  redirects  air  to  the  back 
side  of  diaphragm  A,  which  starts 
diaphragm B on its exhaust stroke. As the 
pump  reaches  its  original  starting  point, 
each  diaphragm  has  gone  through  one 
exhaust  and  one  discharge  stroke.  This 
constitutes one complete pumping cycle. 
The  pump  may  take  several  cycles  to 
completely  prime  depending  on  the 
conditions of the application.

 

HOW IT WORKS 

— AIR DISTRIBUTION SYSTEM

 

 

The Pro-Flo

®

 patented air distribution system incorporates two 

moving parts: the air valve spool and the pilot spool. The heart 
of  the  system  is  the air  valve spool  and  air  valve.  This  valve 
design incorporates an unbalanced spool. The smaller end of 
the  spool  is  pressurized  continuously,  while  the  large  end  is 
alternately pressurized then exhausted to move the spool. The 
spool  directs  pressurized  air  to  one  air  chamber  while 
exhausting the other. The air causes the main shaft/diaphragm 
assembly to shift to one side 

— discharging liquid on that side 

and pulling liquid in on the other side. When the shaft reaches 
the end of its stroke, the inner piston actuates the pilot spool, 
which pressurizes and exhausts the large end of the air valve 
spool. The repositioning of the air valve spool routes the air to 
the other air chamber.

 

 

Section 3 

HOW IT WORKS 

— PUMP

 

 
 
 
 
 

 

 

 

 

 

 
 
 
 
 

 

 

Содержание PSG Wilden PRO-FLO P4 Series

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE P4 Clamped Metal Pump WIL 10183 E 03 Where InnovationFlows ...

Страница 2: ...l Stroke PTFE Fitted 9 P4 Metal Ultra Flex Fitted 10 Suction Lift Curves 11 Section 6 Suggested Installation Operation 12 Maintenance and Troubleshooting Section 7 Disassembly Reassembly 15 Pump Disassembly 15 Air Valve Center Section Disassembly 18 Reassembly Hints Tips 21 Gasket Kit Installation 23 Section 8 Exploded View and Parts List 24 P4 Metal Full Stroke Diaphragm Fitted 24 P4 Metal Reduce...

Страница 3: ...lifornia LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written perm...

Страница 4: ... Pump valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard CAUTION All Wilden pumps are capable of passing solids Usea strainer onthepumpintaketoensurethatthe pump s rated solids capacityisnotexceeded CAUTION Donotexceed8 6bar 125psig air supply pressure CAUTION Theprocess fluidandcleaningfluidsmu...

Страница 5: ...S STAINLESS STEEL VALVE SEAT O RINGS A ALUMINUM BN BUNA N Red Dot FS SANIFLEX Hytrel Cream 1 3 H ALLOY C M MILD STEEL EP EPDM Blue Dot NE NEOPRENE Green Dot PU POLYURETHANE Clear S STAINLESS STEEL VT FKM Silver or White Dot WF WIL FLEX Santoprene VALVE SEAT O RINGS TF PTFE 1 2 3 SPECIALTY CODES 0014 BSP 0023 Wing nuts 0023 Wing nuts 0030 Screen based 0036 Screen based BSP 0044 Stallion balls seats...

Страница 6: ...chamber and mani fold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center block of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inl...

Страница 7: ...8 3 H 262 10 3 J 224 8 8 K 150 5 9 L 178 7 0 M 51 2 0 N 10 0 4 P 338 13 3 R 224 8 8 S 155 6 1 T 193 7 6 U 48 1 9 V 13 0 5 W 91 3 6 LW0338 REV A DIMENSIONS ITEM METRIC mm STANDARD inch A 396 15 6 B 64 2 5 C 206 8 1 D 422 17 4 E 91 3 6 F 138 5 4 G 320 12 6 H 211 8 3 J 262 10 3 K 224 8 8 L 152 6 0 M 178 7 0 N 69 2 7 P 10 0 4 LW0339 REV A DIMENSIONAL DRAWING Section 4 ...

Страница 8: ...umps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P4 METAL TPE FITTED ShipWeight Aluminum 13 kg 29 lb 316 Stainless Steel 20 kg 45 lb Cast Iron 22 kg 49 lb Alloy C 23 kg 51 lb Air Inlet 19 mm 3 4 Inlet 38 mm 1 1 2 Outlet 32 mm 1 1 4 Suction Lift 5 2 m Dry 17 0 8 8 m Wet 29 0 Disp Per Stroke1 1 1 L 0 29 gal Max Flow Rate 307 lpm 81 g...

Страница 9: ...mance pumps should be specified so that daily operation parameters will fall in the center of the pump s performance curve P4 METAL FULL STROKE PTFE FITTED ShipWeight Aluminum 13 kg 29 lb 316 Stainless Steel 20 kg 45 lb Cast Iron 22 kg 49 lb Alloy C 23 kg 51 lb Air Inlet 13 mm 1 2 Inlet 38 mm 1 1 2 Outlet 32 mm 1 1 4 Suction Lift 6 4m Dry 21 0 9 3 m Wet 30 6 Disp Per Stroke1 1 1 L 28 gal Max Flow ...

Страница 10: ...s 4 8 mm 3 16 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 170 lpm 45 gpm against a discharge pressure head of 2 0 bar 30 psig requires 4 1 bar 60 psig and 85 Nm3 h 50 scfm air consumption Caution Do not exceed 8 6 bar 125 psig air supply pressure Flow rates indicated on chart were determined by pumping water...

Страница 11: ...g at 305 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain ...

Страница 12: ...mping volume by counting the number of strokes per minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will...

Страница 13: ...p Anair regulator isusedto regulate air pressure A needle valve is used to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance onpage8 Thisisuseful whentheneedexists to control the pump from a remote location When the pum...

Страница 14: ...ts 7 Check for any broken inner piston that would cause the air valve spool to be unable to shift Pump runs but little or no product flows 1 Check for pumpcavitation Slowpumpspeeddownto allow thick materialtoflowintoliquidchambers 2 Verifythatvacuumrequiredtoliftliquidisnotgreater thanthe vaporpressureofthematerialbeingpumped cavitation 3 Check for stickingballcheck valves a Ifmaterialbeingpumpedi...

Страница 15: ...uitable container Be aware of any hazardous effects of contact with your process fluid NOTE The model photographed for these instructions incorporates rubber diaphragms balls and seats NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Before starting disassembly mark a line from each liquid chamber to its corresponding air chamber This line will assist in proper ali...

Страница 16: ...anifold to expose intake valve balls and seats Inspect ball cage area of liquid chamber for excessive wear or damage Step 7 Remove one 1 set of large clamp bands which secure one 1 liquid chamber to the center section Step 8 Lift liquid chamber away from center section to expose diaphragm and outer piston Step 9A Using an adjustable wrench or by rotating the diaphragm by hand remove the diaphragm ...

Страница 17: ...the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance Step 10 To remove diaphragm assembly from shaft secure shaft with soft jaws a vise fitted with plywood plastic or other suitable material to ensure shaft is not nicked scratched or gouged Using an adjustable wrench remove di...

Страница 18: ...of hazardous effects of contact with your process fluid The Wilden P4 metal pump utilizes a revolutionary Pro Flo air distribution system Proprietary composite seals reduce the coefficient of friction and allow the P4 to run lube free The Pro Flo air distribution system is designed to perform in on off non freezing non stalling tough duty applications Step 1 Loosen the air valve bolts utilizing a ...

Страница 19: ...and gently sliding the spool out of the air valve body Inspect seals for signs of wear and replace entire assembly if necessary Use caution when handling air valve spool to prevent damaging seals NOTE Seals should not be removed from assembly Seals are not sold separately Step 6 Remove pilot spool retaining snap ring on both sides of center section with snap ring pliers Step 7 Remove air chamber b...

Страница 20: ...uring re assembly never insert the pilot spool into the sleeve with the notched end first this end incorporates the urethane O ring and will be damaged as it slides over the ports cut in the sleeve NOTE Seals should not be removed from pilot spool Seals are not sold separately Step 10A Check center block shaft seals for signs of wear If necessary remove shaft seals with O ring pick and replace Ste...

Страница 21: ... or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section Stainless bolts should be lube...

Страница 22: ...e seal to travel down the bushing bore easier 5 With the seal clamped in the pliers insert the seal into the bushing bore and position the bottom of the seal into the correct groove Once the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After the pliers are removed you will notice a slight...

Страница 23: ...move the adhesive covering from the back of the PTFE tape Ensure that the adhesive strip remains attached to the PTFE tape Step 2 Starting at any point place the PTFE tape in the center of the diaphragm bead groove on the liquid chamber and press lightly on the tape to ensure that the adhesive holds in place during assembly Do not stretch the tape during placement in the center of diaphragm bead g...

Страница 24: ...WIL 10183 E 03 Wilden 24 EXPLODED VIEW AND PARTS LISTING P4 METAL FULL STROKE DIAPHRAGM FITTED EXPLODED VIEW Section 8 ...

Страница 25: ...90 03 20 Shaft Pro Flo 1 04 3800 03 700 04 3800 03 700 04 3800 03 700 04 3800 03 700 21 Shaft Stud P4 WAPP Bolt 2 2 08 6150 08 04 6091 08 08 6150 08 08 6150 08 22 Inner Piston 2 04 3700 01 700 04 3700 01 700 04 3700 01 700 04 3700 01 700 23 Diaphragm 2 04 1010 56 24 Outer Piston 2 04 4552 01 04 4550 08 04 4550 03 04 4550 03P 25 Valve Seat 4 04 1120 56 26 Valve Ball 4 04 1080 56 27 Liquid Chamber 2...

Страница 26: ...WIL 10183 E 03 Wilden 26 Exploded View and Parts Listing P4 METAL REDUCED STROKE DIAPHRAGM FITTED EXPLODED VIEW ...

Страница 27: ... 3830 03 700 04 3830 03 700 04 3830 03 700 N A 21 Stud Shaft 2 04 6150 08 04 6150 08 04 6150 08 04 6150 08 Shaft Stud Ultra FlexTM 2 N R 04 6152 08 04 6152 08 N A 22 Inner Piston 2 04 3715 01 04 3715 01 04 3715 01 04 3715 01 Inner Piston Ultra FlexTM 2 04 3760 01 700 04 3760 01 700 04 3760 01 700 N A 23 Back up Diaphragm 2 24 Diaphragm 2 25 Outer Piston 2 04 4600 01 04 4600 03 04 4600 03 04 4600 0...

Страница 28: ...WIL 10183 E 03 Wilden 28 Exploded View and Parts Listing P4 METAL SANIFLO 1935 2004 EC EXPLODED VIEW ...

Страница 29: ...351 03 7 Muffler Plate Pro Flo 1 04 3180 20 700 8 Gasket Muffler Plate Pro Flo 1 04 3500 52 700 9 Gasket Air Valve Pro Flo 1 04 2600 52 700 10 Center Block Assembly Pro Flo 2 1 04 3110 20 11 Sleeve Theraded Pro Flo Center Block 4 04 7710 08 12 Pilot Sleeve Assembly 1 04 3880 99 13 O Ring 009 PilotSpoolRetaining Ø 208 xØ 070 2 04 2650 49 700 14 Seal Shaft 2 08 3210 55 225 15 Gasket Center Block Pro...

Страница 30: ...ts do not require O rings Backup diaphragms for use with PTFE diaphragms only P4 Metal Saniflo 1935 2004 EC Material Diaphragms Reduced Stroke Backup Diaphragms Ultra Flex Diaphragms Full Stroke Diaphragms Full Stroke Backup Diaphragms FDA BUNA N 04 1010 69E N A 04 1020 52E N A N A FDA EPDM 04 1010 74E 04 1060 54E 04 1020 54E N A N A FDA FKM N A N A N A N A N A FDA Wil Flex N A N A N A 04 1040 55E...

Страница 31: ...WIL 10183 E 03 Wilden ...

Страница 32: ...d Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modifythe information and illustrations contained in this document without prior notice This is a non contractual document 05 2018 ...

Отзывы: