Dover PSG WILDEN HS430S Скачать руководство пользователя страница 15

 

WIL-11113-E-04  

15 

HS430S High Pressure Bolted Metal 

 

 

 

 

 

Step 10 

  Step 11 

  Step 12 

Inspect the diaphragm assembly for wear, 
damage or chemical attack. Replace any 
damaged components with genuine 
Wilden parts for reliable performance. 

  To remove the diaphragm assembly from 

shaft, secure shaft with soft jaws 
(aluminum, plastic, or plywood) to ensure 
the shaft is not damaged. Using an 
adjustable wrench, remove the diaphragm 
assembly from the shaft. 

  Remove outer piston and stud if 

equipped. Inspect for wear and replace if 
necessary. 

 

 

 

 

 

 

Step 13 

  Step 14 

Locate the outer piston on the side of the 
amplification chamber has an air 
passageway at the center of the outer 
piston lug. This air passageway allows air 
to flow from the opposite air chamber to the 
amplification chamber. This principle is how 
the HS430S high-pressure pump achieves 
a 2:1 ratio of inlet air pressure to discharge 
pressure. 

  When reassembling the HS430S pump, the outer piston (with the air passageway) has to 

be positioned on the same side as the amplification chamber. If it is not reassembled 
correctly, the pump will not operate, and process fluid will enter the air distribution system 
through the air passageway located at the shaft lug. 
 
This same air passageway continues through the diaphragm shaft, exits out of the 
diaphragm shaft via a 90º turn and into the air chamber located on the wetted side of the 
pump. The air passageway has to be positioned in the air chamber on the wetted side of 
the pump, opposite the amplification chamber. 
 

 

DISASSEMBLY / REASSEMBLY 

Содержание PSG WILDEN HS430S

Страница 1: ...WIL 11113 E 04 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL HS430S High Pressure Bolted Metal Pump ...

Страница 2: ... of PSG California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior wr...

Страница 3: ...nsional Drawings 7 SECTION 5 Performance 8 HS430S Aluminum TPE Fitted 8 HS430S Stainless Steel TPE Fitted 8 Suction Lift Capability 9 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 10 SECTION 7 Disassembly Reassembly 13 Pump Disassembly 13 Air Valve Center Section Disassembly 16 Reassembly Hints and Tips 19 SECTION 8 Exploded View and Parts List 21 ...

Страница 4: ... 180 F air inlet temperature for all models CAUTION All piping valves gauges and other components installed on the liquid discharge must have a minimum pressure rating of 20 7 bar 300 psig CAUTION The discharge pressure generated by this pump is 3X the inlet pressure supplied CAUTION The process fluid and cleaning fluids must be compatible chemically with all wetted pump components CAUTION Before ...

Страница 5: ... FLEX SANTOPRENE THREE BLACK DOTS VALVE SEATS A ALUMINUM S STAINLESS STEEL VALVE SEAT O RINGS TF PTFE WHITE SPECIALTY CODES 0320 Single point exhaust 0323 Single point exhaust DIN flange 0504 DIN flange NOTE Most elastomeric materials use colored dots for identification NOTE Not all models are available with all material options HS430S METAL LEGEND XHS 430S X X X X X X X X X X X X X X X X X 38 mm ...

Страница 6: ...o the air chamber when activated by the inner piston near the end of each stroke FIGURE 1 When air pressure is supplied to the pump the air valve directs pressure to the back side of diaphragm A The compressed air moves the diaphragm away from the center section of the pump The opposite diaphragm is pulled in by the shaft connected to the pressurized diaphragm Diaphragm B is on its suction stroke ...

Страница 7: ...2 6 0 T 170 6 7 U 11 0 4 DIN mm ANSI Inch V 150 DIA 6 1 DIA W 109 DIA 4 5 DIA X 18 DIA 0 9 DIA LW0317 REV A HS430S STAINLESS STEEL DIMENSIONS ITEM METRIC mm STANDARD inch A 443 17 5 B 89 3 5 C 285 11 2 D 292 11 5 E 529 20 8 F 273 10 8 G 50 2 0 H 132 5 2 J 334 13 1 K 321 12 7 L 531 20 9 M 519 20 4 N 86 3 4 P 276 10 9 R 224 8 8 S 178 7 0 T 203 8 0 U 11 0 4 DIN mm ANSI Inch V 150 DIA 6 1 DIA W 109 DI...

Страница 8: ...rs will fall in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure HS430S STAINLESS STEEL TPE FITTED Ship Weight 29 kg 64 lb Air Inlet 3 4 Inlet 38 mm 1 1 2 Outlet 38 mm 1 1 2 Suction Lift 2 0 m Dry 6 8 9 0 m Wet 29 5 Disp Per Stroke1 1 55 L 0 41 gal Max Flow Rate 264 lpm 70 gpm Max Size Solids 6 4 mm 1 4 1Displacement per stroke was calculated at...

Страница 9: ...5 m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain SUCTION LIFT CAPABILITY ...

Страница 10: ...volume by counting the number of strokes per minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assur...

Страница 11: ...tion increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pump will stop No bypass or pressure relief valve is needed and pump damage will not occur The pump has reached a deadhead situation and can be restarted by reducing the flu...

Страница 12: ...pool to be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers s...

Страница 13: ...Be aware of any hazardous effects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Step 2 Step 3 Before starting disassembly mark a line from each liquid chamber to its corresponding air chamber This line will as...

Страница 14: ... expose the valve balls and valve seats Inspect ball cage area of manifold for excessive wear or damage Step 7 Step 8 Step 9 Remove the inlet valve balls and valve seats from the inlet manifold and liquid chambers and inspect for nicks gouges chemical attack or abrasive wear Replace worn parts with genuine Wilden parts for reliable performance Using the appropriate sized wrench remove the liquid c...

Страница 15: ...lug This air passageway allows air to flow from the opposite air chamber to the amplification chamber This principle is how the HS430S high pressure pump achieves a 2 1 ratio of inlet air pressure to discharge pressure When reassembling the HS430S pump the outer piston with the air passageway has to be positioned on the same side as the amplification chamber If it is not reassembled correctly the ...

Страница 16: ...th your process fluid NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Step 2 Step 3 Using a pair of snap ring pliers remove the snap ring from the pilot sleeve Using an O ring pick remove the O ring from modulator spool Using the appropriate sized wrench loosen and remove the fasteners that attach the air chamber to the center section Step 4 Step 5 Step 6 Lift the...

Страница 17: ...r wear to the spool or O rings and replace if necessary Using the appropriate sized wrench loosen the fasteners and lift away remaining air chamber and center block gasket from center section Replace gasket if necessary Step 10 Step 11 Step 12 Using an O ring pick remove the two 2 shaft bushings from center block Inspect and replace if necessary Using an O ring pick gently remove the two 2 Glyd ri...

Страница 18: ...ct for wear and replace if necessary Lift the air valve assembly and remove the air valve gasket Inspect the gasket and replace if necessary Remove the air valve end cap to expose the air valve spool by lifting up on the end cap Inspect the O ring on the end cap using an O ring pick Replace the O ring s if necessary NOTE The Pro Flo SHIFT air valve incorporates an end cap at both ends of the air v...

Страница 19: ...nally the wetted path The applicable torque specifications are on this page The following tips will assist in the assembly process Lubricate the air valve bore center section shaft and pilot spool bore with NLGI grade 2 white EP bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new shaft seals A small amount of NLGI grade 2 white EP beari...

Страница 20: ...r ease 5 With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can...

Страница 21: ...WIL 11113 E 04 21 HS430S High Pressure Bolted Metal SECTION 8 HS430S METAL LW0294 REV C ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST EXPLODED VIEW AND PARTS LIST ...

Страница 22: ...6250 03 71 6250 08 19 Retaining Ring 2 04 3890 03 20 Grounding Screw 10 32 x 1 2 Self Tapping 1 04 6345 08 21 Muffler 1 MNPT 1 15 3510 99R 15 3513 99 15 3510 99R 22 Bushing Reducer 1 1 2 MNPT to 1 FNPT 1 04 6959 08 23 Muffler 1 4 MNPT 1 04 3240 07 Wetted Path Components 24 Liquid Chamber 2 04 5015 03 04 5015 01 25 Manifold Discharge 1 1 2 ANSI 1 04 5047 03 04 5047 01 Manifold Discharge 1 1 2 DIN 1...

Страница 23: ...WIL 11113 E 04 23 HS430S High Pressure Bolted Metal NOTES NOTES ...

Страница 24: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11113 E 04 Where InnovationFlows ...