Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
GPS820/GPS830 METAL
EZ-INSTALL TPE-FITTED
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation
parameters will fall in the center of the pump's performance curve.
GPS820/GPS830 METAL
FULL-STROKE PTFE-FITTED
Ship Weight ...820 Threaded AL 47 kg (104 lb)
830 Flanged AL 54 kg (118 lb)
820 Threaded SS 73 kg (161 lb)
830 Flanged SS 81 kg (178 lb)
Air Inlet ................................... 19 mm (3/4”)
Inlet ............................................51 mm (2”)
Outlet .........................................51 mm (2”)
Suction Lift ....................... 5.5 m Dry (18.2’)
9.0 m Wet (29.5’)
Disp. per Stroke
1
..................2.1 L (0.55 gal)
Max. Flow Rate ............ 645 lpm (171 gpm)
Max. Size Solids ....................6.4 mm (1/4”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 416 lpm (110 gpm)
against a discharge head of 2.1 bar
(30 psig) requires 5.5 bar (80 psig) and
102 Nm
3
/h (60 scfm) air consumption.
Caution: Do not exceed 6.9 bar (100 psig)
air supply pressure.
Ship Weight ...820 Threaded AL 47 kg (104 lb)
830 Flanged AL 54 kg (118 lb)
820 Threaded SS 73 kg (161 lb)
830 Flanged SS 81 kg (178 lb)
Air Inlet ................................... 19 mm (3/4”)
Inlet ............................................51 mm (2”)
Outlet .........................................51 mm (2”)
Suction Lift ....................... 6.1 m Dry (20.0’)
9.0 m Wet (29.5’)
Disp. per Stroke
1
..................2.4 L (0.63 gal)
Max. Flow Rate ............ 636 lpm (168 gpm)
Max. Size Solids ....................6.4 mm (1/4”)
1
Displacement per stroke was calculated at
4.8 bar (70 psig) air inlet pressure against a
2.1 bar (30 psig) head pressure.
Example: To pump 379 lpm (100 gpm)
against a discharge head of 2.1 bar
(30 psig) requires 5.5 bar (80 psig) and
112 Nm
3
/h (66 scfm) air consumption.
Caution: Do not exceed 6.9 bar (100 psig)
air supply pressure.
P E R F O R M A N C E
WILDEN PUMP & ENGINEERING, LLC
10