Dover OPW OT Series Скачать руководство пользователя страница 2

KPTI011-EN rev 

 201

-0

-1

2

 

Please visit OPW’s website: www.opwglobal.com for further information

GENERAL/SAFETY

1. GENERAL

The LPG fueling nozzles are designed to be used for filling LPG vehicles in an operating temperature range of -40°C to 85°C (-40°F to 

185°F).

Nozzle type

Receptacles type

Lock release type

OT300 models 

Italian type dish coupler

Button on side of lever

OTA-300 models 

Button on side of lever

BNA-300 models 

Push button on body

Note: due to the difference in receptacles types, nozzles can only connect to one type of receptacle.

 The pumping system needs to be switched off prior to connection and disconnection. These nozzles have a design feature to vent any 

trapped LPG gas/vapor betseen the vehicle coupler and the nozzle exhaust valve. This feature depends on proper operation of the nozzle 

and the pumping system.

These nozzles are only intended for operation at the following service temperatures:

Nozzle type

Maximum service pressure

Nominal service weight

LPG discharge on discon-
nection

OT300 models 

24 bar (350 psi)

1.45 kg (3.1 lbs)

4.3 cm3

OTA-300 models 

24 bar (350 psi)

1.45 kg (3.1 lbs)

> 1 cm3

BNA-300 models 

24 bar (350 psi)

1.55 kg (3.41 lbs) 

1.6 kg (3.52 lbs)

> 1 cm3

All OPW series nozzles require special installation precautions to ensure safe and reliable operation. The installation shall confirm to the re-

quirements of the authorities having jurisdiction. In absence of requirements, the installation shall comply with standards for LPG vehicle 

fueling systems.

OPW products should be used in compliance with applicable European, national and local laws and regulations. Product selection shall be 

based on physical specifications and limitations, and compability with the environment and material to be handled.

OPW reserves the right to change specifications at any time without incurring obligations.

2. SAFETY

Protective equipment needed:

Safety instructions:

Leather gloves 

Safety glasses 

Face shield 

Closed toe safety shoes

Installation to be performed by authorized personnel only 

Do not smoke or use any open fire or electrical devices that can cause a spark 

Check nozzle for proper operation 

Make sure swivel and lever move freely 

Exhaust (front) gasket must be in place and fully inserted 

Hose, nozzle and swivel must have new O-rings in place prior to installation

WARNING: Make sure hose and nozzle are depressurized before performing maintenance or removing nozzle!

Содержание OPW OT Series

Страница 1: ...AFETY Page 2 INSTALLATION Page 3 OPERATION Page 4 MAINTENANCE Page 5 SPARE PARTS Page 6 WARRANTY Page 7 REVISION HISTORY Page 7 Complies to standards ECER67 EN13463 EN13760 94 9 CE ATEX For use with OPW fueling nozzles OT300 models OTA 300 models and BNA 300 models Italian style coupling and OT321 1 G x 3 4 G adaptor SITE NAME ADDRESS NOZZLE SERIAL NUMBER INSTALLATION CONTRACTOR THIS MANUAL MUST B...

Страница 2: ...5 kg 3 1 lbs 1 cm3 BNA 300 models 24 bar 350 psi 1 55 kg 3 41 lbs 1 6 kg 3 52 lbs 1 cm3 All OPW series nozzles require special installation precautions to ensure safe and reliable operation The installation shall confirm to the re quirements of the authorities having jurisdiction In absence of requirements the installation shall comply with standards for LPG vehicle fueling systems OPW products sh...

Страница 3: ...r from 70 90 Shore A is preferred OPW provides proper O rings with all new nozzles and adaptors 2 Only connect LPG nozzles to certified hoses according to EN1762 3 Turn off pumping system follow good safety practices Lock and tag out system during installation and repair of fueling nozzles 4 Make sure that all sealing surfaces on nozzle and hose are clean smooth and free from other containments 5 ...

Страница 4: ...e outlet gasket is present and fully inserted 5 Initial connection position On OT300 models and OTA300 models Squeeze the lever 1 and then slide the lock release 2 to the side to allow the lever to move forward 3 On BNA 300 models Squeeze the lever 1 and then push the lock release but ton 2 to allow the lever to move forward 3 Then release the lock release button 1 2 3 1 3 2 6 While lever on the n...

Страница 5: ...ing a lint free cloth Do not use any sol vents as this may degrade the seals performance integrity and create a risk for personal injury with subsequent use 2 The entire nozzle should be cleaned and moving parts lubricated periodically by fueling attendant or service personnel This should occur on average once per six 6 months or more frequently if the nozzle is constantly in use or is used under ...

Страница 6: ...KPTI011 EN rev 201 0 1 6 Please visit OPW s website www opwglobal com for further information SPARE PARTS 6 SPARE PARTS For OT OTA nozzles For BNA nozzles For OTA only ...

Страница 7: ... any product which has been altered repaired by any party other than a service representative authorized by OPW or when failure is due to misuse conditions of use or improper installation and maintenance OPW shall in no instance have any liability whatsoever for special incidental or consequential damages to any part and shall have no liability for the cost of labour fright excavation clean up dow...

Страница 8: ...W s website www opwglobal co o o o o om f m f m f m f m m f m f m m m f m f m f m f f f f for or or r r o or or r or o o o or r o o or r fur fur fur fur fu fu fu fu f f r rthe the t the the the e the her i r in nfo nfo o fo f f rma rma rma ma m r a a a a a a a r atio tio tio t tio tio tio tio t on n n n n n n ...

Отзывы: