8
RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul
or damage the lower end at the next start-up.
Place
suction tube into a 1 qt. (0.95 liters) or more container
of fresh filtered water. Flow fresh water through the
injector by operating until container is empty. This
procedure is not needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt, and other debris from
entering the container. Rinse container thoroughly and
often. Do not mix chemicals together that might react
and cause a precipitate. Use
FILTERED
fluid when
filling container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean filter
screen and suction tube (#25) as necessary by rinsing
in fresh water. Replace if necessary. Keep filter screen
off bottom of solution container to prevent dirt and
precipitate from clogging filter.
CLEAN INLET FILTER
Clean or replace inlet filter as required to increase the
life of the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by
using the three valve bypass.
STORAGE
For extended storage, rinse injector using a minimum
of 1/2 gallon. (see "Rinse Injector After Each Use")
Drain water from unit. Inspect lower end seals. Apply
thin coat of silcone to seals and reassemble unit.
Place plugs back into inlet/outlet & suction tube
fitting.
KEEP FROM FREEZING
.
Maintenance
Perform these maintenance
procedures to extend the life of your unit.
NOTE: Maintenance intervals may vary depending on
conditons of use and the chemicals being injected.
Every 3 - 6
Months
Every 6 - 12
months
Replace as
necessary
1. Clean Seal areas
#44.
2. Clean & Check
#64 Seal, #68
Cylinder, clean
and/or replace as
necessary.
3. Clean Filters
1. Replace Dosage
gasket #44.
2. Clean and/or replace
Check Poppet, inside
#11 Suction Tube Fitting.
1. #68 Cylinder
2. #64 O-ring/
Gasket
3. Motor Piston#9
4. #51 & #44
Shaft Assembly
Dosage gasket
5. Check Valve
Assy & Tubing
Reference numbers refer to Page 11-13