10
New Install - Always Pressure Up Slowly (Follow start up on page 8)
Problem
Cause
Solution
No Clicking
Sound
Fluid not flowing through unit
Are the red plugs at the inlet, outlet and suction tube fitting openings removed?
Is the unit installed backward? The arrow on the unit must point in the
direction of the fluid flow.
If still not clicking, do not open the upper body. Call Hydro Systems Customer
Service.
Fluid flowing through unit
Fluid rate is below or exceeds rated service flow of injector. (see Specifications
for maximum flow rate page 4). Maximum number clicks = 50 in 15 seconds.
Ensure all air is out of the unit by pressing the bleeder button in until water
comes out.
If below increase flow rate, if above, reduce flow rate.
Operating pressure exceeds maximum limit. Install a pressure reducer valve.
(see Specifications for maximum flow rate page 4).
Problem
Cause
Solution
Clicking
Sound
No Suction Of
Solution
Cracked or loose Suction Hose
Check for proper fit and /or replace.
Dosage gasket #44 worn or
installed incorrectly
Replace. Ensure during maintenance replacement that #44 dosage
gasket was installed correctly.
Suction tube #25 or suction tube
fitting #11 cracked, leaking or
clogged suction tube filter
Replace and/or clean as necessary.
Check valve #11 leaking
Clean and/or replace as necessary.
Problem
Cause
Solution
Fluid
Re-filling
Solution Tank
Check valve #11 leaking or dirty
Check seat area on suction tube fitting #11. Check valve and seal must
fit loose in the suction tube fitting. Clean seal and inside fitting for debris.
Washer seal on #11 is swollen or
chemical attack
Replace with new check valve assembly.
Problem
Cause
Solution
No Clicking
Sound
Air trapped in unit
Release trapped air by pressing the bleeder button in until water comes
out.
By-Pass Valve not open
Set Valve to the closed position.
Broken Springs
Replace Springs #18, Clean Fluid Filter.
Dirty or plugged inlet filter
Ensure mesh size is correct for proper filtration. Clean filter.
Main Piston Assembly #9 worn
Replace #9 Main Piston Assembly. Clean fluid filter.
Main body #1 worn or scored
Replace Body & Piston.
Troubleshooting
Injector in Operation or After Scheduled Maintenance
Problem
Cause
Solution
Clicking Sound.
Under Injecting or
Unit operates at
high-flow and not at
low flow
#44 Dosage gasket worn
Replace.
#68 Inner Cylinder worn
Replace Inner Cylinder and Gasket #44
Broken Springs
Replace Springs, Clean Fluid Filter.
Main Piston Assembly #9 worn
Replace #9 Main Piston Assembly. Clean fluid filter.
Main body #1 worn or scored
Replace Body & Piston