Congratulations on Your Purchase

We make the best and most reliable fluid-driven injectors 

available. Hydro Systems will provide for replacement of all 

parts proven to be defective in material or workmanship 

from the date of purchase for the following periods: 

 

1

 year

Covers your unit from 

manufacturing and material 

defects only.

Hydro Systems products are warranted to be free from 

defects in materials and workmanship for the above time 

frames. Hydro Systems will at its sole option repair or 

replace any component that fails in normal use. Any repairs 

made under warranty shall not extend the initial warranty 

period.

To Maintain Your Warranty

Your only responsibility is ordinary maintenance - filtering 

incoming fluid, replacing the O-ring and dosage piston/

gasket when worn. Seals and O-rings are not covered under 

the warranty

To Return an injector for Warranty or Non-Warranty repair:

Contact Hydro Systems Company or your local distributor for return information.

Warranty

This warranty is not valid if the defects are found to be due to 

the product’s misuse, lack of maintenance, fluid impurities 

such as sand or iron, defective installation, freezing,  fluid 

hammer, abuse, unwanted side effects due to the chemicals 

you choose to inject or service provided by anyone who is not 

an authorized service provider. Hydro Systems declines any 

responsibility if the product is not used

 

in compliance with the 

operating instructions and specifications as indicated in this 

owner’s manual. 

IN NO EVENT SHALL HYDRO SYSTEMS BE LIABLE FOR ANY 

INCIDENTAL, SPECIAL; INDIRECT, OR CONSEQUENTIAL DAMAGES, 

WHETHER RESULTING FROM THE USE, MISUSE OR INABILITY TO 

USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT.

There is no warranty expressed or implied relating in any way 

to products used in conjunction with Hydro Systems.

Hydro Systems or authorized distributor shall not be liable for 

incidental or consequential damage, such as any economic loss. 

Hydro Systems retains the exclusive right to repair or replace the 

product. Such remedy shall be your sole and exclusive remedy 

for any breach of warranty. There are no warranties, expressed 

or implied, which extend beyond those described above.

Содержание Hydro systems AquaBlend 0.2%-2% WSP

Страница 1: ...perating Manual Adjustable Lower End Fluid Flow Range 0 04 gpm to 11 gpm 10 2500 l hr Injection Range 0 2 to 5 1 500 to 1 20 Operating Pressure 5 to 90 psi 0 3 to 6 2 bar Model 0 2 2 WSP Model 0 78 5 WSP ...

Страница 2: ...Quick Start Guide 0 04 11 gpm 5 90 psi 10 2500 l h 0 34 6 2 bar ...

Страница 3: ...models are designed to inject liquid concentrate or soluble powder that are recommended and approved for injection into fluid systems lt is the responsibility of the operator to determine the correct dosage settings of the unit using the chemical manufacturers recommendation for dispensing their product and to assure that proper dosage is being maintained Maintenance and Warranty Hydro Systems off...

Страница 4: ...ng 3 4 npt ght bsp Housing Polyacetal POM Dosing Accuracy 10 of ratio Repeatability 5 Pressure Loss Available Upon Request Maximum Temp 100ºF 38 C Minimum Temp 34ºF 1 C Maximum vertical suction of concentrate 13 Feet 396 Centimeters Maximum horizontal suction of concentrate 49 Feet 1493 Centimeters Self Priming Yes Seal Material Available Viton acids oils pesticides Alternative material available ...

Страница 5: ...to thoroughly dissolve the chemical will cause premature wear to the dosage piston gasket and the inner cylinder Please read this instruction manual thoroughly Following the procedures will increase the life of your injector Warning Please read precautions thoroughly before operation Must meet all applicable local codes and regulations Avoid a Potentially Hazardous Chemical Accident Select a safe ...

Страница 6: ...is adjustable EVEN WHILE OPERATING AND UNDER PRESSURE To change feed rate see Fig 1 and Fig 2 Do not remove 79 when injector is under pressure 1 Lift lock ring on 7 Fig 1 2 Rotate Ratio Adjuster Sleeve bottom of 7 Fig 2 up or down to the desired setting Use arrows at top of the Ratio Adjuster Sleeve to line up with the desired feed rate on the sleeve 3 Return ring to lock position by pushing down ...

Страница 7: ...tube fitting Using the inlet side as a shut off valve could cause full strength solution to siphon into the feed line Solution Container Use any size container A lid or cover is recommended To connect your solution container gently push the end of the suction tube onto the bottom of the suction tube fitting assembly Place the filter into the solution container at least 2 above the bottom and fill ...

Страница 8: ... FILTER Clean or replace inlet filter as required to increase the life of the unit as well as reduce pressure loss BYPASS INJECTOR When not in use place the injector in bypass mode by using the three valve bypass STORAGE For extended storage rinse injector using a minimum of 1 2 gallon see Rinse Injector After Each Use Drain water from unit Inspect lower end seals Apply thin coat of silcone to sea...

Страница 9: ...urface of shaft replace shaft Step 6 Place new motor piston carefully into pump body and replace lid Step 5 Remove motor piston from pump body Step 7 Place shaft into the motor piston Step 9 Replace lower end assembly onto the pump body Step 4 Hold body firmly and unscrew the lid If lid is tight use 1 25mm socket to loosen Step 8 Rotate shaft 90 to lock into place Gently pull down to ensure shaft ...

Страница 10: ...acked leaking or clogged suction tube filter Replace and or clean as necessary Check valve 11 leaking Clean and or replace as necessary Problem Cause Solution Fluid Re filling Solution Tank Check valve 11 leaking or dirty Check seat area on suction tube fitting 11 Check valve and seal must fit loose in the suction tube fitting Clean seal and inside fitting for debris Washer seal on 11 is swollen o...

Страница 11: ...11 Injector Repair Parts BSP GB GB 18 Part Description of Part 102801BSP AquaBlend Body BSP 017200GB Motor Piston Replacement Kit H 017202GB Replacement Cover Kit Kit L ...

Страница 12: ...t Description of Part 017210WSP 2 Adj AquaBlend Dosage Gasket Kit A 017211WSPGB 2 Adj AquaBlend Wear Kit Kit B 017213WSPGB 2 Adj AquaBlend Check Valve Kit D 017214WSPGB 2 Adj AquaBlend Maint Kit Kit E 017216WSPGB 2 Adj AquaBlend Complete Lower End Kit G 10095359GB Pick Up Tube Assy 2 ...

Страница 13: ...on of Part 017220WSP 5 Adj AquaBlend Dosage Gasket Kit A 017221WSPGB 5 Adj AquaBlend Wear Kit Kit B 017223WSPGB 5 Adj AquaBlend Check Valve Kit D 017224WSPGB 5 Adj AquaBlend Maint Kit Kit E 017226WSPGB 5 Adj AquaBlend Complete Lower End Kit G 10095356GB Pick Up Tube Assy 5 ...

Страница 14: ... warranty is not valid if the defects are found to be due to the product s misuse lack of maintenance fluid impurities such as sand or iron defective installation freezing fluid hammer abuse unwanted side effects due to the chemicals you choose to inject or service provided by anyone who is not an authorized service provider Hydro Systems declines any responsibility if the product is not used in c...

Отзывы: