Daily:

When fi nished using the pump for the day, run the pump two to four minutes with the select valve and 
nozzle in rinse position, to purge chemical from the unit.  See Fig. G.
Set the nozzle to “S” (keep the select valve in the rinse position) and run for ten seconds.
Turn the unit off with the switch.  Relieve the pressure in the discharge hose by pulling the trigger on the 
spray attachment after the switch has been turned off.  A small amount of water will discharge.
Unplug unit.
Check the unit for any damage or leakage.
If the unit is going to be stored where it can freeze, drain the water reservoir and run the pump until there 
is no more water in the system.  Allow the system to thaw before you start the pump.

NOTE:  Failure to follow this procedure after use will void the warranty on the pump.

1.

2.
3.

4.
5.
6.

Maintenance:

The power switch is lighted when it is in the “ON” position.  See Fig. G.
The pump will run when the trigger on the spray attachment is pulled and stop when it is released.
The rollover valve on the outlet of the spray attachment selects between the two attached spray 
nozzles.  “S”should be used when applying either product, “R” is used for rinsing.  The rinse is a fi ne 
spray pattern, while the “S” is a pattern that is more coarse.
Run the unit approximately 10 seconds to fl ush prior chemical from hose.

NOTE:  To apply either chemical you must use nozzle “S” for proper dilution.

1.
2.
3.

4.

Normal Operation:

CAUTION: Continuous cycling of the pump (continuous, rapid on/off cycles) indicates a problem 
with the unit.  Have the unit serviced immediately.

6

Out of water/chemical indication:

When the system runs out of either water or chemical, air will enter the water stream and it will become 
“rough.”  The pump may also continue to run when the trigger is released.  Turn off the power immedi-
ately, fi ll the water reservoir and/or replace the empty product container, and repeat the priming operation.

Содержание Hydro ICS 8800

Страница 1: ...ICS 8800 Integrated Cleaning System 120 Volt AC ...

Страница 2: ...ON Dispense cleaners and chemicals in accordance with manu facturer s instructions observe safety and handling instructions of the chemical manufacturers equipment after each use to maintain proper operation Unit with integral 12 5 gallon water reservoir Spray attachment w 2 nozzles installed 14 ft discharge hose installed 2 Bottle holders for 1 gal rectangular bottles 2 Bottle holders for 1 gal r...

Страница 3: ...f your facility easier This unit includes the following features 14 ft discharge hose Locking casters Spray attachment with two nozzles solution and rinse Storage for spray bottle Fresh water reservoir 12 5 Gal Chemical bottle holder Top Easy roll wheels 110 Volt AC GCFI plug 3 Tap style drain ...

Страница 4: ... the metering tip opening and the viscosity of the liquid being siphoned For water thin products the chart can be used as a guideline Because dilution can vary with water temperature and pressure and if the product is noticeably thicker than water dilution rates shown should be viewed as approximate Orifice Size Tip Color Average Dilution Ratio no tip 4 1 0 128 grey 4 25 1 0 098 black 4 5 1 0 070 ...

Страница 5: ...n is not visible Press the test button Verify that the red band on the rest button ap pears Press and release the reset button Turn the power switch on The pump should run for a short time then stop The pump will run until the discharge pressure reaches the factory set point The pump will then turn off until the trig ger on the spray attachment is activated Direct the spray nozzle into a drain or ...

Страница 6: ...d when it is in the ON position See Fig G The pump will run when the trigger on the spray attachment is pulled and stop when it is released The rollover valve on the outlet of the spray attachment selects between the two attached spray nozzles S should be used when applying either product R is used for rinsing The rinse is a fine spray pattern while the S is a pattern that is more coarse Run the u...

Страница 7: ...d without tools See Fig H Leak in one of the fittings Remove the cart top and find the source of bubbles Correct the leak Pump pulses There is a pressure switch in the pump If the pump is pulsing this switch is cycling and the life of the pump will be greatly reduced Have the pump serviced Pump not running Reset GFCI on plug See Fig I Check to see if fuse is blown fuse is panel mounted in dash To ...

Страница 8: ...ement Kit AC 5 10091864 Discharge Hose Replacement Black 6 690014 Metering Tip Kit 7 10076302 Foot Valve EPDM 8 10091860 Chemical Feed Line Assembly 9 10091861 Fill Port Cap with Cleat 10 10091868 Switch Replacement Kit 11 10091867 Caster Replacement Kit 12 90084615 Tap Style Drain 13 10091866 Wheel Replacement Kit Parts List 1 2 3 4 5 7 8 9 6 10 11 12 13 ...

Отзывы: