11
1
2
3
4
5
6
7
8
9
10
11
Product 01
(E04) (E05) (E06) (E07) (E08) (E09) (E10) (E11) (E12) (E13)
Product 02
Product 03
Product 04
Product 05
Product 06
Product 08
Product 09
Product 07
Product 10
1 2 3 4 5 6 7 8 9
10
C
2.O5 Electrical Connections
(continued)
Input: Air Pressure Sensor Connections
If your system includes the optional Air Assist Flush feature, you must connect the Air Pressure Sensors to the main panel on
Bank X3. The Channel 1 sensor at M, L1+ and E02, and the Channel 1 sensor at M, L1+ and E03 as shown below.
Remove
the jumper wires from L1+ to E02 and from L1+ to E03.
If the Air Pressure sensors are not being connected, those
jumper wires must be in place or the system will go into alarm when the air pressure test is performed.
Channel 1
Pressure Sensor
Channel 2
Pressure Sensor
1) Brown Wire to M 1) Brown Wire to M
2) Yellow Wire to L1+
2) Yellow Wire to L1+
3) Gray Wire to
E02
3) Gray Wire to
E03
Input: Drum Level Sensor Connection
The Dositec Product Drum Lances have a built-in level
sensor that can tell the system if the chemical drum is
empty.
You can have as many as ten of the level sensors connected
to the main panel, on Bank X3 using E04 through E13 and
L1+ for the common ground connection.
Wire supplied by installer, colors may vary.
Wire 1) Product 01 connects to E04
Wire 2) Product 02 connects to E05
Wire 3) Product 03 connects to E06
Wire 4) Product 04 connects to E07
Wire 5) Product 05 connects to E08
Wire 6) Product 06 connects to E09
Wire 7) Product 07 connects to E10
Wire 8) Product 08 connects to E11
Wire 9) Product 09 connects to E12
Wire 10) Product 10 connects to E13
Wire 11)
Common ground always
connects to L1+
2.OO installation
(continued)
?