Dover Ebsray R75 Скачать руководство пользователя страница 2

 

 

3. 

The materials and method of fabrication of any required 

sub-systems.  

 

It is the responsibility of the designer, fabricator and the installer 
of each required sub-system to ensure that:  
 

a) 

The Ebsray specifications within this publication and any 

other  relevant  Ebsray  documents  are 

STRICTLY

 

adhered to. 

b) 

Any  variation  (including  the  use  of  equipment  deemed 

"Equivalent")  or  addition  to  Ebsray  specifications,  as 
related to the pumpset and pumping system in general, 
meet Ebsray's minimum requirements.  

 
 
 

c) 

All design, fabrication and installation of the tank and sub-
systems  is 

STRICTLY

  in  accordance  with  all  relevant 

National, State and Local Directives, Standards, Codes and 
Regulations. 

d) 

All equipment is suitable for the hazardous area as defined 
by EN6079.10.1 

e) 

All 

Essential Health and Safety Requirements (EHSR’s) as 

outlined in EN60079.14, EN15198, EN ISO 80079-36 and 
EN ISO 80079-37 are adhered to. 

 

This product is CE marked (meaning the equipment has been 
assessed and supplied in conformity to those Directives), strict 
adherence with all instructions and recommendations forms an 
essential part in maintaining the product/equipment’s conformity. 
Failure to comply with the instructions and recommendations 
contained in this Publication may void CE conformity. 

 

 

SECTION 2 - PUMP DATA

2.1 

PUMP IDENTIFICATION 

A pump identification tag, containing the pump serial 
number, I.D. number, and model designation, is attached to 
each pump.  It is recommended that the data from this tag 
be recorded in SECTION 2.3. If replacement parts are 
needed, or if information pertaining to the pump is required, 
this data must be furnished to an Ebsray representative. 
 
The R75 pump is 

listed by Underwriters’ Laboratories for 

liquefied petroleum gas service. 
 

2.2 

TECHNICAL DATA 

Maximum Operating 
Temperature 

135°C (275°F) 

Maximum Pump Speed 

3450 RPM 

Maximum Differential 
Pressure 

1400 kPa (14 Bar) 

Maximum Working 
Pressure 

2920 kPa  (29.2 Bar) 

Technical Data is for standard materials of construction.  
Consult Ebsray Material Specs for optional materials of 
construction. 

 

2.3 

INITIAL PUMP START UP INFORMATION 

Model No. 

 
 

Serial No. 

 
 

Equipment No. 
 

 

Date of 
Installation 

 

Inlet Gauge 
Reading 

 

Discharge 
Gauge Reading 

 

Flow Rate 

 
 

 

 

Failure to set the vehicle emergency 

brake and chock wheels before 
performing service can cause severe 
personal injury or property damage 

 

 

Failure to relieve system pressure prior 
to performing pump service can cause 
serious personal injury or property 
damage.

  

Systems with meters will still be 

pressurized even after the hose is 
emptied

 

 

 

 

Hazardous 

machinery can 

cause serious 

personal injury.

 

 

Hazardous pressure 

can cause serious 

personal injury or 

property damage 

 

 

 

 

 

 

Failure to disconnect and lockout 

electrical power or engine drive before 
attempting maintenance can cause 
severe personal injury or death 

 

 

Operation without guards in place can 
cause serious personal injury, major 
property damage, or death. 

 

 

 

Hazardous 

machinery can 

cause serious 

personal injury.

 

 

Do not operate 

without guard  

in place

 

 

 

 

 

 

 

Disconnecting fluid or pressure 
containment components during pump 
operation can cause serious personal 
injury or property damage.

 

 

 

 

 

 

 

Hazardous pressure 

can cause serious 

personal injury or 

property damage 

 

 

 

 

 

 

 

Содержание Ebsray R75

Страница 1: ...rsonal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property damage NOTE Indicates special instructions which are very important and must be followed 1 3 ESSENTIAL HEALTH SAFETY REQUIREMENTS This publication is intended to assist those involved with the installation op...

Страница 2: ...ION 2 3 If replacement parts are needed or if information pertaining to the pump is required this data must be furnished to an Ebsray representative The R75 pump is listed by Underwriters Laboratories for liquefied petroleum gas service 2 2 TECHNICAL DATA Maximum Operating Temperature 135 C 275 F Maximum Pump Speed 3450 RPM Maximum Differential Pressure 1400 kPa 14 Bar Maximum Working Pressure 292...

Страница 3: ...ransit should be noted on the packing note and on both your own and the carrier s copy of the consignment note Should a shortage be evident on receipt notify Ebsray immediately giving full details and packing note number Additionally a claim should be made with the transport company When received on site the pump set must be stored in a dry covered area NOTE Never allow water or any corrosive prod...

Страница 4: ...TO driven Hydraulic motors should be well supported with their shafts parallel to the pump shaft in all respects Ebsray provides an optional close coupled hydraulic motor adapter The adapter provides for straight alignment of a hydraulic motor drive through a coupling connected to a straight key pump shaft 3 9 PUMP INTERNAL RELIEF VALVE NOTE The pump internal relief valve is designed to protect th...

Страница 5: ... such conditions as excessive heating of ball bearings vibration or unusual noises NOTE Consult SECTION 7 of this manual if difficulties during start up are experienced and troubleshooting is required 4 3 PERIODIC INSPECTION Periodic inspection of the Pump Pump System and Ancillary Equipment is required to maintain safety conformity operational functionality and reliability If any abnormal conditi...

Страница 6: ...ust be fully flushed out i e returned in the state it was provided Numbers in parentheses i e Cover 2 following individual parts indicate reference numbers specified in SECTION 6 Steps before disassembly 1 Obtain the appropriate Work Permit if required 2 Isolate power supply to motor if fitted 3 Isolate pump from liquids in inlet and discharge lines depressurise and purge out any toxic flammable c...

Страница 7: ...tridge 10 Fit the smallest new O ring 48 to the Seal Seat and lightly lubricate 11 Without removing the protective cover press the Seal Seat into the Cartridge with fingers ensuring complete and square engagement 12 Remove the protective cover from the Seal Seat clean with non residue contact cleaner 13 Fit the new O rings 57B 57C to the Cartridge and lightly lubricate The smaller cross section O ...

Страница 8: ...ubricated new O ring 3 Remove the Bypass Spring Then remove the Valve 105 If the Valve is stuck use pliers or similar to pull the Valve out NOTE Be careful not to scratch the Valve with the pliers as any foreign materials left inside the pump WILL seriously damage the pump 4 Fit the new Valve and or Bypass Spring then the Valve Cover 5 Ensuring the valve cover O ring is located properly hand fit t...

Страница 9: ...ousing 1 101 Adaptor Flange Elbow 1 27 Cap Head Setscrew 8 101A Adaptor Flange Elbow Plug 1 33 Dust Seal Bearing 1 102 Blanking Flange 1 34 Key Driver 1 103 Valve Cover 1 40 Seal Seat 1 103A O ring Valve cover 1 41 Seal Face 1 103B Cap Head Setscrews 4 42 Seal Sleeve 1 104 Bypass spring 1 45 Seal Spring 6 105 Valve 1 46 O ring Shaft 1 106 Spring Cap 1 47 O ring Seal Sleeve 1 106A O ring Spring Cap...

Страница 10: ......

Страница 11: ... Foreign matter in discharge line Collapsed or kinked discharge hose Pressure Viscosity Temperature or Speed not as per design conditions Foreign matter jamming parts Pump out of alignment with driver Parts worn End of service life or adverse pumping conditions Excessive Noise Foreign matter jamming parts Parts worn End of service life or adverse pumping conditions Incorrect driver speed Faulty or...

Страница 12: ...12 NOTES Visit www ebsraypumps com au for more information on any Ebsray products 156 South Creek Rd Cromer 2099 Australia Telephone 612 9905 0234 Fax 612 9938 3825 Email sy sales psgdover com ...

Отзывы: