Publication No.: 2750-17
11
SECTION 7
– TROUBLESHOOTING
Symptom
Possible cause
Symptom
Possible cause
No Liquid
Delivery
No power to drive shaft
Coupling damaged or disengaged
Foreign matter in the pump
Ball Bearings seized
Inlet/Discharge valves closed
No liquid in supply tank
Incorrect direction of rotation
Strainer blocked
High static discharge pressure
Inadequate N.P.S.Ha
Pump vapour lock
Reduced
Output
Incorrect driver speed
Faulty driver
Discharge piping restricted
Strainer blocked
Inlet piping too small or too long
Foreign object in suction line
External bypass pressure setting too low
End of service life or adverse pumping
conditions
Excessive
Power
Consumption
Foreign matter in discharge line
Collapsed or kinked discharge hose
Pressure, Viscosity, Temperature or
Speed not as per design conditions
Foreign matter jamming parts
Pump out of alignment with driver
Parts worn
End of service life or adverse
pumping conditions
Excessive
Noise
Foreign matter jamming parts
Parts worn
End of service life or adverse pumping
conditions
Incorrect driver speed
Faulty or incorrect size driver
Leakage
from Pump
Seals incorrectly installed
Excessive dry running or pump
O-rings nicked, cut or twisted
O-rings not compatible with liquid
Worn or damaged shaft in seal zone
Misalignment causing excessive
shaft distortion
Excess system pressure
O-ring failure
Fasteners not tightened to specified
torque.
Thermal expansion of product when
locked between valves either side of
pump
Excessive static pressure
Seal faces cracked, scratched, pitted
or dirty
Содержание Ebsray R75