background image

 

 

 

 

 

 

 

PRODUCT INSTALLATION 

PRECAUTIONS – WARNINGS – ADDITIONAL INFORMATION 

(RETAIN THIS DOCUMENT) 

 

IMPORTANT SAFEGUARDS 

 

Read  Instructions 

-  All  the  safety  and  operating  instructions  should  be  read 

before the unit is operated.

 

Retain Instructions 

- The safety and operating instructions should be retained for 

future reference.

 

3. 

Heed Warnings 

- All warnings on the unit and in the operating instructions 

should be adhered to.

 

4. 

Follow Instructions 

- All operating & user instructions should be followed.

 

5. 

Electrical Connections 

- Only a qualified electrician should make electrical 

connections.

 

6. 

Attachments 

- Do not use attachments not recommended by the product 

manufacturer as they may cause hazards.

 

7. 

Cable Runs 

- All cable runs must be within permissible distance.

 

8. 

Mounting 

-This unit must be properly and securely mounted to a supporting 

structure capable of sustaining the weight of the unit accordingly:

 

a.  Installation should be made by a qualified installer.

 

b.  Installation should be in compliance with local codes.

 

c.  Care should be exercised to select suitable hardware to install the unit, 

taking into account both the composition of the mounting surface and 
the weight of the unit. Be sure to periodically examine the unit and the 
supporting structure to make sure that the integrity of the 
installation is intact. Failure to comply with the foregoing could 
result in the unit separating from the support structure and falling, with 
resultant damages or injury to anyone or anything struck by the failing 
unit.

 

 

SERVICE

 

If the unit ever needs repair service, customer should contact Dotworkz Systems 

+1 

(619) 224-LIVE (5483)

 for return authorization & shipping instructions.

 

CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE 

COMPONENTS TO WATER OR MOISTURE

 

 

The lightning flash with an arrowhead 
symbol, within an equilateral triangle, 
is intended to alert the user to the 

presence of non-insulated "dangerous 
voltage" within the

 product's enclosure 

that may be of sufficient magnitude to 
constitute a risk of electric shock to 
persons

 

 

The exclamation point within an 
equilateral triangle is intended to 
alert the user to the presence of 
important operating and 
maintenance (servicing) instructions 
in the literature accompanying the 
appliance 

UNPACKING

 

Unpack carefully. Electronic components can be damaged if improperly handled

 

or dropped. If an item appears to have been damaged in shipment, replace it 
properly in its carton and notify the shipper. 

Be sure to save:

 

1

. T

he shipping carton and packaging material. They are the safest material in 

which to make future shipments of the equipment.  
2. These Installation and Operating Instructions.

 

 

 

 

For technical questions or product returns – call Dotworkz Customer Service (866-575-4689) 7:30 AM to 4:30 PM (PST).  The proper 
technician will contact you as soon as possible. 

 

 

The External Nut on All electrical wire feed Glands must be tightened to create a weather tight seal prior to putting S-TYPE in 
service.  Failure to create this seal may result in water incursion into enclosure.  This may lead to electrical shock, product failure and 
damage to electrical systems installed within enclosure, including but not limited to damage to camera, heater and blower circuitry, 
cooling circuitry and other systems installed in unit. 

 

 

All screws on hinged lower must be tightened to create seal on enclosure.    Failure to create this seal may result in water incursion into 
enclosure.  This may lead to electrical shock, failure and damage to electrical systems installed within enclosure, including but not limited 
to damage to camera, heater and blower circuitry, cooling circuitry and other systems installed in unit. 
 

 

Do not over tighten any Screws, Stand Offs, or other fasteners on this unit.  Failure to heed this warning will cause damage or failure of 
the S-TYPE enclosure. 
 

 

Содержание COOLDOM ST-CD

Страница 1: ...INSTALLATION GUIDE Mounting Sealing of Housing Electrical Details S Type COOLDOME ENCLOSURE ST CD 12V DC ST CD 24V DC COOLDOME Enclosures...

Страница 2: ...d to any of the following abuse improper use negligence accidents lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outline...

Страница 3: ...hin an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of...

Страница 4: ...to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camera...

Страница 5: ...conduit feed mouth 4 Push plug into conduit mouth with finger tips till it flush with outside of fitting 5 Repeat steps 1 4 for any other conduit feeds as needed 6 To assure an airtight seal caulk ar...

Страница 6: ...ted and kept off while installing or Servicing Enclosure Follow All Local and Applicable Electrical Codes and Standards for Installation of Electrical components All Cable Ports wire feeds or Conduit...

Страница 7: ...nly 1 10 Power Supply S 250 indoor style in COOLDOME option only 1 Included in S Type Package Not Included in this Package Camera Installation Tools Wall Mounting Bolts Hardware Pole Mount Straps Stra...

Страница 8: ...Socket wrench or box open end wrench or adjustable wrench Wire stripping tool For Wall Mounting Drill and Bits for user supplied fasteners for wall mounting enclosure For Pole Mounting Strapping Band...

Страница 9: ...enclosure Always create a drip loop between all external conduit or cable connections between fittings and S Type Housing All cable feeds must be sealed before S Type housing is put into service to pr...

Страница 10: ...S Type Strong Arm Mount Wall Mounting Pattern Not to Scale...

Страница 11: ...ays consult and follow all local and applicable electrical codes to install and service housing Always shut off power before installation and follow all applicable safety practices and guidelines Only...

Страница 12: ...afety Ground Front of Power Supply with terminal strip Rear of Power Supply with Input Voltage Selector Select Input Voltage before Hooking up Power Supply 110 VAC or 220 VAC Low Voltage 12 VDC Output...

Страница 13: ...24V DC Low Voltage Wire Gage Selector Chart Per Conductor Pair Per Cooler...

Страница 14: ...Voltage 90 132VAC 176 264VAC Selected by Switch Frequency Range 47 63 HZ Input Current Full Load Typ 4A 115VAC 2A 230VAC Recommended Min Circuit Breaker for 110VAC In 10 A type C Int Electrical Worki...

Страница 15: ...plate organize camera parts to be installed Using bolt provided mating camera to mount bracket Adjust camera to sit strait and slightly overhang front of mounting bracket Gently but securely tighten b...

Страница 16: ...voltage on wires pulled in from power supply before attaching wires to assure Low Voltage 12 VDC input wires and proper polarity Hook up 12VDC to red terminal and DC ground wire to black terminal Tigh...

Страница 17: ......

Отзывы: