background image

 

Specifications 

Air Velocity 

Range 

Resolution 

Accuracy 

m/s (meters per sec) 

0.40 - 30.00 m/s 

0.01 m/s 

± (3% + 0.20 m/s) 

km/h (kilometers/hour) 

1.4 - 108.0 km/h 

0.1 km/h 

± (3% + 0.8 km/hr) 

ft/min (feet per minute) 

80 – 5900 ft/min 

1 ft/min 

± (3% + 40 ft/m) 

mph (miles per hour) 

0.9 – 67.0 mph 

0.1 mph 

± (3% + 0.4 MPH) 

knots (nautical MPH) 

0.8 to 58.0 knots 

0.1 knots 

± (3% + 0.4 knots) 

Air Flow

 

Range 

Resolution 

Area 

CMM (cubic meters/min) 

0-9999

00

 m

3

/min 

0.001 to 100  0 .000

 to 

999.9

m

2

 

CFM (cubic ft/min) 

0-9999

00

 ft

3

/min 

0.001 to 100 

0.000

  to

 999.9

ft

2

 

Range 

Resolution 

Accuracy 

Air Temperature

 

14 - 140

o

F (-10 - 60

o

C)

 

0.1

o

F/C

 

4.0

o

F (2.0

o

C)

 

Circuit

 

 

 

Custom LSI microprocessor circuit 

Display

   

 

Dual function 0.7" (16 mm) 4-digit LCD 

Sampling rate

 

 

1 reading per second approx. 

Sensors

 

Air velocity/flow sensor: Conventional angled vane arms with 
low-friction ball bearing 

Temperature sensor: NTC-type precision thermistor 

Automatic Power off 

Auto shut off after 20 minutes to preserve battery life 

Operating Temperature

 

32 to 122°F (0 to 50°C) 

Storage Temperature 

14 to 140

o

F (-10 to 60

o

C) 

Operating Humidity

 

<80% RH 

Storage Humidity   

<80% RH 

Operating Altitude

  

2000 meters (7000ft) maximum 

Battery

   

 

One 9 volt (NEDA 1604) battery 

Battery life

 

80 hours approx. (if the Backlight is used continuously, battery 
life will be reduced significantly) 

Battery Current

 

 

8.3 mA DC approx. 

Weight

   

 

1.6 lbs. (725g) including battery & probe 

Dimensions

 

 

Main instrument:: 203 x 75 x 50mm 

Sensor Head: 2.75” (70mm) Diameter

 

Содержание VA893

Страница 1: ...User s Manual VA893 Thermo Anemometer ...

Страница 2: ...CITY mode the meter displays air speed UP also serves as increase number button in AREA mode AVG Used to Average multiple readings in FLOW or VELOCITY mode Up to 20 readings can be averaged HOLD Press to freeze the displayed reading Press again to unlock display This button also functions as the RIGHT scroll button in AREA mode AREA NEXT Press and hold to manually enter the area of a duct in CFM o...

Страница 3: ... HOLD bottom of LCD Data Hold for the Air Velocity and Air Flow function o C o F Temperature units of measure CFM CMM airflow units of measure AREA ft2 m2 units for area dimensions m s ft min km h MPH knots air velocity units of measure X10 X100 multipliers for air flow readings AVG air averaging mode REC indicates that min max function is running top for temp bottom for air Large LCD digits at bo...

Страница 4: ...sticker placed inside the vane 4 View the readings on the LCD Display The large main LCD display shows the Air Velocity reading The upper right LCD sub display shows the temperature reading Air Velocity Averaging Mode 1 To enter 20 Point Averaging Mode press and hold the AVG button until it beeps twice The AVG icon will be displayed 2 Take a measurement and press the AVG button A single beep will ...

Страница 5: ...Push the NEXT button to scroll thru and select the desired location Once you have selected the desired memory location enter your dimension Use the UP button to change the flashing digit Use the LEFT button to move the decimal Use RIGHT button to select the other digits After all of the digits are entered press and hold the AREA button until it beeps twice to save the area into memory and return t...

Страница 6: ...p automatically after 2 hours and the upper LCD sub display will show a OFF only in the average mode 4 Press the MAX MIN button again to display current readings NOTE the meter will keep recording MAX MIN AVG readings 5 To clear and stop MAX MIN AVG recording and return to normal operation press and hold the MAX MIN button until the meter beeps twice Automatic Power OFF To conserve battery life th...

Страница 7: ...oprocessor circuit Display Dual function 0 7 16 mm 4 digit LCD Sampling rate 1 reading per second approx Sensors Air velocity flow sensor Conventional angled vane arms with low friction ball bearing Temperature sensor NTC type precision thermistor Automatic Power off Auto shut off after 20 minutes to preserve battery life Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140o F...

Страница 8: ...lae Unit of Measure Conversion Table m s ft min knots km h MPH 1 m s 1 196 87 1 944 3 6 2 24 1 ft min 0 00508 1 0 00987 0 01829 0 01138 1 knot 0 5144 101 27 1 1 8519 1 1523 1 km h 0 2778 54 69 0 54 1 0 6222 1 MPH 0 4464 87 89 0 8679 1 6071 1 Width W Height H Area A Width W x Height H CFM ft3 min Air Velocity ft min x Area ft2 CMM m3 min Air Velocity m sec x Area m2 x 60 Radius Area A o x r2 Where ...

Страница 9: ...9 ...

Отзывы: