![Dosmatic Superdos 45 0.3% PAA Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/dosmatic/superdos-45-0-3-paa/superdos-45-0-3-paa_operating-manual_2524092011.webp)
English
English: 11
Routine Maintenance Instructions
Step 1.
Unscrew LOWER END
CYLINDER ASSEMBLY
from body.
Step 2.
Remove LOWER END
CYLINDER ASSEMBLY .
Step 4.
Pry the #15 SEAL RETAINER from
the injector. Pry #17 O-ring from the
unit. NOTE: O-ring may still be
seated at the base of the unit.
Step 3.
Rotate #51 SHAFT 90º and pull
from body.
Step 5. For 2.5% & 5%
Replace #44 DOSAGE PISTON
flared-end up and #14 O-ring.
0.3% only: Replace # 51 SHAFT
ASSEMBLY. See Step 5a.
Step 6
.
Reinsert #15 SEAL RETAINER
and #17 O-ring onto # 51
SHAFT ASSEMBLY.
Step 7.
Reinsert #51 SHAFT ASSEMBLY into
body and rotate 90º to lock. Confirm
the shaft is locked in by gently
tugging on the shaft. Shaft should
remain inserted.
Step 8.
Screw LOWER END CYLINDER
ASSEMBLY onto body. Ensure
#16 gasket is seated on the top
of cylinder assembly.
Step 5a. For 0.3%.
Replace LOWER SHAFT assembly