NO !
©
DOSATRON INTERNATIONAL /
21
©
DOSATRON INTERNATIONAL /
20
IMPORTANT ! - Do not put the suction tube strainer on the bottom of
the stock solution container. The strainer must be suspended at least
4”[10cm] above the bottom of the tank to avoid sucking up the insoluble
particles that may damage the injection assembly (Fig.2).
- Do not put the strainer on the ground.
Under no circumstance should the solution level be above the water
inlet of the DOSATRON (to avoid siphoning situations) (
Fig. 3)
.
ASSEMBLING THE DOSATRON (cont...)
Fig. 2
WHAT YOU SHOULD DO
WHAT YOU MUST NOT DO
▼
▼
INSTALLATION HINTS
EXCESSIVE FLOW (as an indication)
If your DOSATRON clicks more than
46 times,
that is
23 cycles in 15
seconds*
, you are close to the superior flow limit. If you need more flow, you
must install a DOSATRON with a superior capacity of flow.
*D14MZ520 = 30 times, 15 cycles
The DOSATRON can be connected to
the main water line
directly (Fig. 4)
;
on a
by-pass (Fig. 5)
, recommended.
If your flow rate is above the ope-
rating limits of the DOSATRON, see
EXCESSIVE FLOW.
To prolong the working life of the
DOSATRON it is advisable to install
a filter (ex.: 300 mesh - 60 microns
depending on your water quality)
upstream.
This is imperative if the water contains
impurities or particles, especially if the
water comes from a well.
A filter is recommended and requi-
red for the warranty to be valid.
Installing the DOSATRON on a bypass
enables clean water to be supplied
without operating the DOSATRON
and the DOSATRON to be easily dis-
mantled.
When connecting an
installation to the public water
supply, you must respect the
rules and regulations in force
in the country.
Fig. 4
Check
valve
Valve
Valve
Filter
Filter
Fig. 5
Fig. 3
1
0cm
4"
US