www.doerrfoto.de
DÖRR GmbH Fotomarketing • Postfach 1280 • 89202 Neu-Ulm/Germany
1.1 Charging
1. Turn off power station
before charging
1.2 LED lights while charging
Red LED is blinking:
no charging
Red LED lights continuously:
in charging process
Green LED lights up:
charging completed
2. Connecting devices with LFP12
1. Turn main switch (4)
to „O = Off“.
Note:
• Turn off the modelling light of your flash to achieve a longer battery performance.
• After switching the main switch (4) to “I=On”, the power station will run a short detection after a peep. During the detection, colours
of the LEDs at control unit will change. After a few seconds follows another peep and status LED (7) lights up green. The detection is
complete and the power station is working.
• When using for outdoor photography, a waterproof housing (optional) is recommended. Make sure that the housing does not
cover the fan inlet and outlet.
V. Function Modes
1. Flash Mode
The flash mode is especially for the use with flashes. The standby function is not available in this mode.
For the use with non-flash devises please select “Normal Mode”.
Peak power: approx. 1500W for 2 seconds.
Example: 2 studio flashes à 1000Ws with recycling time of 2 seconds can be easily operated (for about 200 flashes).
2. Insert the charging cable (25)
into the charging socket (17).
3. Connect the AC power cable (27)
with AC input socket (24).
Note:
When battery is empty it takes about 3 hours to fully charge the power
station. Remove the cables when charging is complete. To extend battery
life please fully charge power station:
1. each time after using the power station
2. when the power station has not been used for about 100 days
2. Connect your device with
one of the 3 AC output
sockets (2).
3. Turn main switch (4)
to „I = On“.
4. Turn mode selection
(15) to required mode
(Flash or Normal)
5. Turn on the connected
device. Now the device
draws power from
power station.
Recycling time
Flash power
Recycling time with power station
1 second
up to 800Ws
no change
1 second
exceeds 800Ws
becomes longer but does not exceed 5 seconds
2-3 seconds
up to 2400Ws
no change
2-3 seconds
exceeds 2400Ws
becomes longer but does not exceed 5 seconds
3 seconds
up to 3000Ws
no change
3 seconds
exceeds 3000Ws
becomes longer but does not exceed 5 seconds
LFP12 Mobile Power Station 230V
Instruction Manual
GB