www.doerrfoto.de
DÖRR GmbH Fotomarketing • Postfach 1280 • 89202 Neu-Ulm/Germany
2. Functions
2.1 LED indicators
LED Battery indicator (5)
LED Power indicator (6)
2.2 Mode selection (15) –refer to capture V
The mobile power station has two different operation modes:
•
Flash
: Special mode for use with flashes. In this mode the standby function is not available;
built-in battery can stand by for about 13 hours.
•
Normal
: For use with non-flash electronic devices. In this mode the standby function is available;
built-in battery can stand by for about 55 hours. Not recommended for use with flashes.
2.3 Main switch (4)
O = OFF Power station is powered off
I = ON
Power station is powered on; ready to use
II = USB Power station enters into USB charging mode. When LED USB indicator (10) lights up, electronics with USB interfaces
e.g. iPhone and iPad can be charged over the USB sockets (8).
USB 1
power output 5V/2000mA
USB 2
power output 5V/1000mA
USB 3
power output 5V/500mA
2.4 AC output sockets (2)
• The 3 AC output sockets are in parallel connection and each of them can output the maximum power.
• The AC outputs are universally applicable for each country, no adapter needed.
• Standard voltage: 230V/50Hz or 110V/60Hz
IV. Operation instruction
1. Installation and detachment of battery unit
Installation
• Place the control unit on the battery unit.
• Close all 4 locks (11) to connect the two units together securely.
Detachment
• By pressing in the middle of the locks, the locks can be opened easily.
• Remove the control unit from the battery unit.
LED
Battery voltage
Red, blinking
<10.7 oder > 15.4 V
Red
10.7 ~ 11.2 V
Orange
11.2 ~ 12.3 V
Green
12.3 ~ 14.6 V
Orange, blinking
14.6 ~ 15.4 V
• In loaded operation, the LED light changes when battery voltage goes down.
The higher the load power is, the more abruptly LED light changes.
• In loaded operation, the power station will shut down automatically if the power
indicator (6) blinks frequently and the buzzer alarms for over 5s. In this case, the
remaining battery power is too low to afford the current load. Please charge it for
use.
LED
Output power
Off
0-35 W
Green
35~230 W
Orange
230~520 W
Red
520~670 W
Red, blinking
> 670 W
LED Status indicator (7)
LED
Status
Red
Off no working
Green
On working
LFP12 Mobile Power Station 230V
Instruction Manual
GB