Filter sump downwards
Fig. 3: Installation at bottom (example)
1
Material inlet
The filter can be used for circulation. Air
presses directly through the material outlet
(2) into the high pressure hose. Material run-
ning through the lateral material outlets (2),
(3), (4) is filtered. Material running through
the lower material outlet (5) circulates and is
not filtered. A pressure gage can be con-
nected to the filter on top (2) or on the side
(4).
If the filter sump is installed below, a
pressure relief valve must be con-
nected on the side (4) of the filter.
4.3
Assembly
Personnel:
Mechanic
+ additional qualification explosion pro-
tection
+ Additional qualification high pressure
Protective equipment:
Protective gloves
Face protection
Protective workwear
Safety boots
Fig. 4: Assembly drawing (example of filter
above)
Observe the following at assembly:
NOTICE!
Property damage due to free-standing
filter
If the free-standing filter is attached, tor-
sional forces act on the pipelines when
opening and closing the filter sump. The
threads are damaged.
– Install filter through a support block or
on the pump.
Assembly
01/2020
Filter HP - MFT00003EN