3.2
Handling of packaging material
ENVIRONMENT!
Incorrect disposal
Incorrectly disposed packaging material
can damage environment.
– Dispose of material no longer required
in an environment-friendly manner.
– Observe local disposal specifications.
3.3
Storage
Storage provisions:
Do not store outdoors.
Store Filter only when dry.
Store in a dust-free place.
Do not expose to aggressive media.
Protect from solar radiation.
Avoid mechanical vibrations.
Temperature: 10°C to 40°C
Relative humidity: 35% to 90%
4
Assembly
4.1
Requirements for the
Installation point.
It should be possible to disconnect every
power supply to the filter and secure it
against reconnection.
The air supply must be adjustable.
Lines, seals and screw connections must
be designed for the requirements of the
filter.
The filter must be accessible for mainte-
nance work.
Provide pressure release device to avoid
excess pressure.
4.2
Installation position
Install the filter vertically. The filter sump can
face up or down.
Filter sump upwards
Fig. 2: Installation on top (example)
1
Material inlet
The filter is used as compressor. Air presses
up in the filter and keeps the fill level con-
stant. Prevent pressure drops in the con-
nected product and minimize pulsations. Up
to four application devices can be connected
to the connections (2), (3).
If the filter sump is installed above, a
pressure relief valve must be
attached to a connection (2), (3).
Assembly
01/2020
Filter HP - MFT00003EN
7/36