WARNING!
Material escaping under pressure
Material leaking under high pressure can
penetrate the body. Even if the injury looks
like a harmless cut wound, the penetrating
material leads to amputation, serious inju-
ries can cause death.
– Do not try to seal leakages using body
parts, gloves or towels.
– If there are injuries, seek medical
attention immediately.
Before working on the product:
– Disconnect the system, in which the
product is installed, from compressed
air and material supply.
– Secure the system against being
switched on again.
– Depressurize the lines.
WARNING!
Danger of explosion due to chemical
reactions
Material, halogenated hydrocarbon-based
rinsing agent or cleaning agent can chemi-
cally react with aluminum components of
the product. Chemical reactions can cause
explosions. Serious injury and death could
be the consequence.
– Only use purging agents and cleaning
agents that do not contain any halo-
genated hydrocarbons.
NOTICE!
Unsuitable cleaning agents
Unsuitable cleaning agents can damage
the product.
– Only use cleaning agents approved by
the material manufacturer.
– Follow safety data sheets.
– Place heavily soiled components in a
cleaning bath.
– Only place those parts in the
cleaning bath, which are suitable for
the cleaning bath.
– Use only electrically conductive
containers.
– Ground the container.
– Do not use ultrasound baths.
Use alcohols (isopropanol, butanol) for
non-flammable coating materials.
Remove dried non-flammable coating
materials using a material manufacturer-
approved organic thinner.
NOTICE!
Damage due to unsuitable cleaning
tools
Unsuitable cleaning tools can damage the
product.
– Only use cloths, soft brushes and
paintbrushes.
– Do not use abrasive cleaning tools.
– Do not poke blocked nozzles with met-
allic objects.
– Do not use compressed air for
cleaning.
– Do not use any thinner spray guns.
– Do not use high pressure for cleaning
agents.
Cleaning
02/2020
EcoGun AA AUTO - MSG00008EN