The fuse power of the power supply fuse must be consistent with the power and type of the

dehumidifier. The fuse should be installed near the dehumidifier. The selection of power
supply cable and main fuse should be equipped with the correct operation power of the wet
unit. Fuse rated value: 16A 250V

If the power cord is damaged, in order to avoid danger, it must be replaced by the

manufacturer, its maintenance department or similar department.
•On the power line, L1, L2, L3 are connected with three fire wires on the fixture, and the N is
connected with the zero line, PE and ground are connected. If the display board displays E3,
please switch any two lines of L1, L2 and L3.

Chapter 3. Operation Control

3.1 Button function instruction

1.“Power” button

Press this button to start the machine, it enters start-up mode after the buzzer buzzes twice.

Press this button to stop the machine, it enters stop mode after the buzzer buzzes once.

2. “Set” button

Press this button for once, and it enters the mode of setting required humidity.

3. “+” button

4. Press this button directly to increase the set humidity. Buzzer buzzes once for each

pressing and the set humidity increase by 1% RH. Successive operation can be achieved by

pressing this button successively

5. “-” button

Press this button directly to decrease the set humidity. Buzzer buzzes once for each

pressing and the set humidity decrease by 1%RH. Successively operation can be achieved

by pressing this button successively.

3.2 Operating the machine

1. Energize the power, the dehumidifier will beep for once;

2. Press the “POWER” button for once, the LCD display is light. After all the displays are

normal, the LCD displays current environment humidity;

3. Setting of humidity: press “+” and “-“ buttons to set the required humidity. When the set

humidity is 3% less than current humidity, the dehumidifier works; when the set humidity is

3% more than current humidity, the dehumidifier stops.

4. When the set humidity is less than 10%, the dehumidifier enters the mode of successive

dehumidification.

Содержание CD-090

Страница 1: ...ng Dorosin and we highly recommend you to have a careful reading of the instructions before using the devices It will provide you with necessary information for proper use and maintenance Pictures ins...

Страница 2: ...2 1 Brief Introduction 4 2 2 Shipping and Storage 4 5 2 3 Inspection 5 2 4 Electrical Connections 5 6 Chapter 3 Operation Control 6 3 1 Button Function Instruction 6 3 2 Operating the Machine 6 7 Cha...

Страница 3: ...self and others Electrical components must be maintained by authorized electrical installation personnel The equipment is not explosion proof and is forbidden to be used in inflammable and explosive p...

Страница 4: ...ose of this manual is providing necessary information for users to comprehend the structure and function of the equipment and guide users about installation operation maintenance and basic fault analy...

Страница 5: ...al connections works must be done by local professionals and shall be carried out by qualified personnel Dehumidifier control circuit has been marked with different color to prevent confusion unit des...

Страница 6: ...enters stop mode after the buzzer buzzes once 2 Set button Press this button for once and it enters the mode of setting required humidity 3 button 4 Press this button directly to increase the set hum...

Страница 7: ...idifier is going to be spared for a long time please unload the power cord or cut the power 7 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds t...

Страница 8: ...Clean the stopper 3 Place the water tank well Frost formation There id frost on the surface of dehumidifier It s normal the machine can defrost automatically The dehumidifier has a slight wobble A sl...

Страница 9: ...of the motor so no additional maintenance is required The motor startup capacitor should be checked every year to ensure its normal condition 6 4 Maintenance Procedures The procedures for inspection a...

Страница 10: ...g and unloading Failure and damage caused by not operating according to the operation manual Failure or damage caused by the removal repair or modification of the product without the authorization of...

Страница 11: ...tion Manual 1 piece 3 Warranty Card 1 piece 4 Certificate of Qualification 1 piece Guangdong Dorosin Electric Appliance Co Ltd Add Room 2018 2019 2nd floor No 228 Huadi Avenue Liwan District Guangzhou...

Отзывы: