dormakaba TS93 GSR PT Installation Instructions
08281850
08-2019
TS93 GSR Surface Applied Closers
3
Technical specifications
1 Technical specifications
1.1 Overview
Door Width
Closer
Interior/
Exterior
1'-3"
min.
2’-6"
max.
3’-0”
max.
3’-6”
max.
4’-0”
max.
4’-6”
max.
5’-0”
max.
TS9315
Interior
•
•
NA
NA
TS9356
Interior
NA
NA
NA
NA
•
•
•
Caution: sex nuts are required for attachment of
components to unreinforced doors and to wood
or plastic faced composite type fire doors, unless
an alternative method is identified in the
individual door manufacturer’s listings.
Maximum door opening degree is 175°.
Minimum door width is 23”.
Hold open range is from 80° to 130° with optional
hold open kit.
Arrows on closer mounting plate point upward.
A carry bar should be installed to insure that the
active door is opened enough for the inactive
door to close.
Recommended carry bars:
DORMA carry bar MK-397 (up to 3’-6” wide door)
DORMA carry bar MK-398 (3’-6” and wider door)
Installation instructions are included with carry
bar.
Follow included template to properly prepare
door and frame for all accessories of the closer
installation.
Know the swing of the door which is being
installed prior to installation.
Make sure door efficiently operates prior to
installing closer.
Verify closer spring size prior to installation.
Table 1
Table 2
Drill bits:
Pozidriv PZ-2
2.5mm, 3mm, 5mm hex key
Metal: No. 21 & 10-32 tap
#2 Phillips screwdriver
1/2” box wrench
Wood: 1/8”
3/16” flat head screwdriver
10” adjustable wrench
1.2 Size selection chart
1.3 Tools recommended