background image

dormakaba TS93 GSR PT Installation Instructions

08281850

08-2019

TS93 GSR Surface Applied Closers

9

Adjust closing speeds

Adjust hold open

Adjustments

Confirm closer spring size prior to making any 
closing speed adjustments.
Do not back valve heads out beyond closer casting.

Door should close in 3 to 6 seconds from 90º.

Maximum opening angle is 175º.

Do not close valves completely.

3.1  Adjust closing speeds: sweep, latch, backcheck, delayed action

Fig.9 

  

3.2.1 

Adjust door position:

• 

Adjust hold open angle: loosen adjustment 
screws using an M2 hex key.

• 

Slide hold open mechanism to desired location 
and re-tighten adjustment screws.

3.2.2 

Hold open activation:

• 

Place door in hold open.

• 

Deactivate: When clips are released from slide 
shoe.

• 

Activate: When clips are pressed against inside 
of slide shoe.

3.2.3 

Adjust hold open force:

• 

Decrease force: spin dial away from door frame

• 

Increase force: spin dial towards door frame

NOTE: Do not set release force too high. Damage may 
occur to door, hinges or GSR system.

3.2  Adjust optional hold open

Fig.10 

Increase

Decrease

Decrease

Increase

Backcheck & 

Delayed action

Sweep & Latch

Speed 

3.1.1 

Adjust the 

closing

 

sweep speed

 for the area from 70° - 0°

• 

Increase sweep speed: Turn valve counter-clockwise

• 

Decrease sweep speed: Turn valve clockwise.

3.1.2 

Adjust the 

closing latch speed 

for the area from 7° - 0°.

• 

Increase latch speed: Turn valve counter-clockwise

3.1.3 

Adjust the 

opening backcheck

 for the area from  

70° - 175°.

• 

Increase resistance: Turn valve clockwise

• 

Decrease resistance: Turn valve counter-clockwise.

3.1.4 

Adjust the 

closing delayed action

 for the area from  

135° - 70°.

• 

Increase delayed action: Turn valve counter-clockwise

• 

Decrease delayed action: Turn valve clockwise

Latch

Backcheck

Sweep

Latch

Backcheck

Delayed action

175°

135°

70°

Sweep

Delayed action

Adjustment 

screws

Dial

Hold open 

mechanism

Содержание TS93 GSR PT

Страница 1: ...TS93 GSR PT Surface Applied Closer Push side track mount and coordinator system Installation instructions 08281850 08 2019 EN ...

Страница 2: ... 4 Surface closer system 4 1 5 Handing the door 4 2 Installation instructions 5 2 1 Installing the back plate 5 2 2 Installing the surface closer 5 2 3 Installing the slide channel 6 2 4 Installing the main arm 6 2 5 Secure main arm 7 2 6 Installing the coordinator system 8 3 Adjustments 9 3 1 Adjust closing speeds sweep latch backcheck delayed action 9 3 2 Adjust optional hold open 9 3 3 Adjust s...

Страница 3: ... open kit Arrows on closer mounting plate point upward A carry bar should be installed to insure that the active door is opened enough for the inactive door to close Recommended carry bars DORMA carry bar MK 397 up to 3 6 wide door DORMA carry bar MK 398 3 6 and wider door Installation instructions are included with carry bar Follow included template to properly prepare door and frame for all acce...

Страница 4: ...or Interior side of door Left hand door LH Right hand door RH The surface closer is comprised of the following components 1 Closer body B body 2 Main arm 3 Active track assembly 4 Inactive track assembly 5 Pinion 6 Track covers and center cover 7 Closer cover 8 Closer end caps 9 Connecting channel 1 5 Handing the door Fig 2 1 4 Surface closer system 7 8 3 4 3 4 6 9 6 5 1 2 2 ...

Страница 5: ...our 10 32 x 5 8 PH screws 10 x 1 1 2 wood screws provided for each plate NOTE Ensure arrows point in direction of arm location Left hand door Right hand door Backplate 10 32x5 8 2 1 2 Secure left and right hand mounting angles to frame Use 3 FH screws each 2 1 3 Cut middle filler angle Secure using 2 FH screws Mounting angles Mounting angle flat head screws Mounting angles Middle filler angle Midd...

Страница 6: ... FH screws 2 3 3 Insert end caps into track 2 3 4 Secure end of track through end caps Use two M5 FH screws 2 3 5 Slide end cap covers onto end caps 2 3 Installing the slide channel Fig 5 2 4 1 Attach 1 2 wrench to bottom pinion 2 4 2 While looking up rotate pinion square until it aligns to square hole on arm LH turn 5 counter clockwise RH turn 5 clockwise 2 4 3 Arm is parallel to door 2 4 4 Secur...

Страница 7: ...er bolt and an 5mm hex key NOTE Depress trigger dial to allow active slide shoe to move freely If locking pin falls out discard after completing installation 2 5 2 Close both doors 2 5 3 Press lever with roller against door 2 5 4 Tighten hex screw 2 5 5 REMOVE alignment screw Arm Slide shoe Shoulder bolt Left hand door Active Right hand door Inactive Trigger dial Lever with roller Hex screw Alignm...

Страница 8: ...Open active leaf to retract clamping rod 2 6 7 Active door Insert connecting channel into trigger dial 2 6 8 Inactive door Insert connecting channel into plastic guide 2 6 9 Unwind trigger dial away door frame until active door starts to close Clamping plate should be perpendicular to clamping rod 2 6 10 Tighten set screw to secure trigger dial NOTE The locking pin can be discarded once system has...

Страница 9: ... open force Decrease force spin dial away from door frame Increase force spin dial towards door frame NOTE Do not set release force too high Damage may occur to door hinges or GSR system 3 2 Adjust optional hold open Fig 10 Increase Decrease Decrease Increase Backcheck Delayed action Sweep Latch Speed 3 1 1 Adjust the closing sweep speed for the area from 70 0 Increase sweep speed Turn valve count...

Страница 10: ... latch the door TS9356 NOTE Supplied with a size 6 spring setting Increase force turn clockwise 6 times max Regular Mount Pull side closers Closer size Max door weight lbs Door width Full turns Interior Exterior TS9315 2 100 2 6 0 3 125 3 2 6 3 4 150 3 6 3 9 5 200 4 3 6 12 TS9356 5 200 4 3 6 4 6 250 4 6 4 0 4 Install covers 4 1 1 Snap both end covers onto closer body end caps 4 1 2 Remove un neede...

Страница 11: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...

Отзывы: