STV 50x

2018-11

WN 059725 45532

dormakaba Mounting instructions

Mounting

4.3.2  Mount STV 505 or STV 506

STV 505
STV 506

1

4.4

approx. 100 mm

Ø 3 mm

1.

2.

STV 505
STV 506

2

Exchange only as a complete unit.
Do not separate the striking plate from the 
locking unit!

4.

3.

appr

ox. 180 mm

Содержание STV 50 Series

Страница 1: ...ence of action steps 6 Reference to a chapter Door opening direction DIN left opening outwards to the right Door opening direction DIN right opening outwards to the left Components may be damaged by electrostatic discharge Ground your own body before touching a component 2 Safety 2 1 Intended use The STV 50x is an electromechanical locking device based on the quiescent current principle 2 2 Requir...

Страница 2: ...DIN L STV 508 with flat striking plate and latch guide for rebated doors DIN R Fig 1 STV 502 STV 506 STV 508 Variants for doors DIN right 3 2 Parts included STV 50x in one of the above mentioned variants Bag with fixing materials 3 3 Technical information Locking force Supply voltage 2000 N at UB 10 24 V DC 15 Power consumption 75 mA Temperature range 10 C to 55 C Rel humidity up to 93 non condens...

Страница 3: ...STV 50x 2018 11 WN 059725 45532 dormakaba Mounting instructions Mounting 4 3 Mounting the variants 4 3 1 Mount STV 501 or STV 502 1 STV 501 STV 502 approx 100 mm Ø 3 mm 2A 4 3 5 6 2 approx 180 mm 4 3 5 6 ...

Страница 4: ...akaba Mounting instructions Mounting 4 3 2 Mount STV 505 or STV 506 STV 505 STV 506 1 4 4 approx 100 mm Ø 3 mm 1 2 STV 505 STV 506 2 Exchange only as a complete unit Do not separate the striking plate from the locking unit 4 3 approx 180 mm ...

Страница 5: ...akaba Mounting instructions Mounting 4 3 3 Mount STV 507 or STV 508 1 STV 507 STV 508 4 4 approx 100 mm Ø 3 mm 3 2 1 STV 507 STV 508 approx 180 mm 4 2 Exchange only as a complete unit Do not separate the striking plate from the locking unit ...

Страница 6: ...cks STV xxx are connected via the DCW bus assign different DCW bus addresses to the electrical door locks Service button press service button for 8 seconds factory setting LED displays LED On LED Off LED flashes DCW LED red Bus connection OK Bus connection interrupted DCW error Config LED yellow Configuration successful Device not configured Both LEDs Configuration mode active 4 5 Complete mountin...

Страница 7: ...reverse order of mounting and must be carried out by qualified personnel The product must be disposed of in an environmentally friendly manner Electro technical parts and batteries must not be disposed of as domestic waste Dispose of electrotechnical parts and batteries in the designated acceptance and collection points Refer to the statutory regulations for your country ...

Страница 8: ...dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com Translation of the original document subject to change without notice ...

Отзывы: