Select Combination Length:
To change the Combination Length, click on the up and down arrows. A combination length of 6 to 9 digits can be selected.
Example: 7 digits (Figure 6)
CAUTION:
To maintain the VdS Class 2 and EN 1300 Class B certification when the Silent alarm feature is used, a
combination length of 7 digits or longer must be selected.
Select External Signals (Alarm Box required - P/N 2789NC):
By placing a check mark in the desired option, select either Disable Opening, Remote Time Delay Override, or Remote
Override. (Figure 7).
Disable Opening:
• Input signal to the Alarm Box will disable the opening of the lock by a valid combination.
Remote Time Delay Override:
• Input signal to the Alarm Box will disable the time delay, and allow the opening of the lock by any valid combination.
Remote Override:
This option is ONLY available with
Lock code level 39E v1.09 or higher
.
Remote Override is typically used by the banking industry, and changes how the lock is accessed.
• Input signal to the Alarm Box will enable opening of the lock using only one valid combination.
• If there is no input signal, then the lock can be opened by entering two valid combinations.
WARNING:
The silent alarm will be activated, if the lock is opened using the two combination method
Select Time Delay:
The Delay and Open Periods may be set up in this window. Enable feature by placing a check mark in the Time Delay On
box. Then enter the desired time period in the text box or use the up and down arrows to select the time periods.
Example: 15 min Delay Period and 5 min Open Period (Figure 8).
• A Delay period between 1 - 99 minutes may be selected.
• An Open period between 1 - 19 minutes may be selected.
Note: If Time Delay On is not selected, this feature is inactive. This feature may be enabled later by the Manager. (Refer to
ComboGard Pro Manager Instructions 732.018.)