ComboGard Pro locks can either be configured using the 
ComboGard Pro Setup software or through a series of 
keypad commands. This document will cover configuring the 
lock using both methods. 

The ComboGard Pro Lock has three states of operation: 

Factory Default, Manual Setup

, and 

Active

. ComboGard 

Pro locks are shipped from LA GARD in Factory Default 
state without Users or features enabled. 

Factory Default:

 The Lock must be in the Factory Default 

state to be programmed by the PC software. 
Factory mode functions as follows: 
• 

1

 key – When pressed, will open the Lock. 

• 

0

 key – When pressed, prompts the ComboGard Pro Setup 

software to send the configuration settings to the Lock. 

OR

 if pressed and held, places the Lock into Manual Setup. 

•  All other keys perform no function. 

Manual Setup:

 The Lock can be configured using the 

keypad only. 

Active:

 To activate the Lock and freeze the configuration, 

the Manager combination MUST be changed. 

PROGRAMMABLE LOCK FEATURES 

MODES

 (Multiple Modes may be selected.)

• 

 Silent  Alarm

 (Alarm Box Required - P/N 2789NC)  

If enabled, this option will send a signal to an outside 
alarm system through the LA GARD Alarm Box. 

• 

 Dual  Mode

 

In Dual Mode, two combinations are required to open the 
lock. Manager Commands 1,2,3,7 and 9 can be performed 
using the Manager combination alone. 
In “Dual Mode and [User + Manager] to access Manager 
Menu”, two combinations are required for all lock functions 
except to Change Combination. A valid User combination 
must be entered first, followed by the Manager 
combination to access Manager Commands 1,2,3,7 and 9.

• 

 Time Delay Override 

If enabled, User 9 can override delay period. 
User 9 must be active. 

EXTERNAL SIGNALS

 (Alarm Box Required - P/N 2789NC. 

Only one External Signal type may be selected.) 
An external input signal to the Alarm Box will either disable 
the Lock from opening, override the time delay, or enable the 
remote override depending on the selection programmed for 
External Signals.
•   External Signal disables Lock opening with valid 

combination. 

OR

 External Signal overrides Time Delay. (This option is 

ONLY available if enabled using Setup software.) 

OR

 External Signal enables the Remote Override. (This 

option is ONLY available if enabled using Setup software, 

and with Lock code level 39E v1.09 or higher.

)

TIME DELAY  

•  Delay Period 1 - 99 minutes 
•  Open Period 1 - 19 minutes 

NOTE: 

If the Time Delay On is not selected, then this 

feature is inactive. This feature may be enabled later. 
(Refer to Manager Instructions 732.018.)

COMBINATION LENGTH 

A combination length from six (6) to nine (9) digits may be 
selected.

NOTE: 

To maintain the VdS Class 2 and EN 1300 Class 

B certification when the duress alarm feature is used, a 
combination length of 7 digits or longer must be selected.

LOCK USERS 
Manager 

•  Open Lock 
•  Change Combination 
•  Enable/Disable Users 
•  Delete Users 
•  Set Time Delay Values 
•  Audit Lock 

Up to 9 Users 

•  Open Lock 
•  Change Combination

STANDARD LOCK FEATURES 
Wrong Try Penalty  

•  Entry of four (4) consecutive invalid combinations initiates 

a five (5) minute delay penalty. 

•  Lock responses during the penalty period are as follows:
 -  The LED will flash every ten (10) seconds. 
 -  If any key is pressed, the Lock will flash the LED and 
beep three times.
•  Once the penalty period has ended, two (2) consecutive 

invalid combinations will initiate another five (5) minute 
penalty period. 

Low Battery Warning 

•  Repeated audio/visual signals (LED flashes/beeps) during 

Lock opening indicate the battery is low and should be 
replaced immediately.

•  If the battery level becomes too low to safely operate the 

Lock, pressing any key will initiate the low battery 
warning. The battery must be replaced before the Lock 
will operate. 

Audit Records 

•  Lock records the last 63 events in non-volatile memory. 
•  Audit file cannot be deleted from the Lock. 
•  Only the Manager can audit the Lock.
•  ComboGard Pro auditing software and an Interface 

Adapter are required to retrieve a Lock audit.

Содержание LA GARD ComboGard Pro 39E

Страница 1: ...Setup Instructions LA GARD ComboGard Pro 39E Electronic Lock P N 731 018 Rev I 05 2018 ...

Страница 2: ...pening override the time delay or enable the remote override depending on the selection programmed for External Signals External Signal disables Lock opening with valid combination OR External Signal overrides Time Delay This option is ONLY available if enabled using Setup software OR External Signal enables the Remote Override This option is ONLY available if enabled using Setup software and with...

Страница 3: ...The LED will flash once every second Open Period The LED will flash twice a second and the Entry Device will beep every 10 seconds If any key is pressed the Lock will flash the LED and beep three times Penalty Period The LED will flash every ten 10 seconds Low Battery Warning During a Lock opening the LED will flash and Entry Device will beep repeatedly SUPER MASTER RESET SMR SMR will reset the lo...

Страница 4: ... be displayed Figure 1 Figure 1 Select the COM Port When the Setup program is started it identifies the COM Ports that are currently available on your PC You must select the COM Port to be used when communicating with the lock each time you start the program 1 Access the Device Manager to determine which COM Port to select for the Setup Software by completing the following steps a Right click on M...

Страница 5: ...is currently installed will follow the device description Figure 2 Figure 2 If using a Serial Adapter identify the standard Serial COM Port to be used Standard Serial COM Ports are identified in the list with a description of Communications Port 2 From the Setup software select the Configuration menu on the Menu bar The list of available COM Ports will be displayed 3 Select the appropriate COM por...

Страница 6: ...stalled The software will automatically install User 1 with the default combination 1 1 1 1 1 1 if no other User s are selected for installation Figure 4 Figure 4 Time Delay Override If selected User 9 must be installed to use this option The software will automatically install User 9 without combination Figure 5 The Manager can choose to enable the w Combination option or enroll User 9 through th...

Страница 7: ...his option is ONLY available with Lock code level 39E v1 09 or higher Remote Override is typically used by the banking industry and changes how the lock is accessed Input signal to the Alarm Box will enable opening of the lock using only one valid combination If there is no input signal then the lock can be opened by entering two valid combinations WARNING The silent alarm will be activated if the...

Страница 8: ...to the lock port marked ENT 2 Connect power to the lock through the Entry Device 9 volt battery or by connecting a LA GARD battery box or AC Power Adapter to the lock port marked BAT 3 Plug the Interface Adapter with the appropriate programming cable into PC 4 Plug the programming cable into the audit programming port of the Entry Device Figure 10 5 Click on the Transmit button in the software Fig...

Страница 9: ... Figure 14 SAVE SETUP CONFIGURATION Once the setup configuration has been completed you may name and save the setup file xml for future use 1 Click the Save button or on the Files tab at the top of the program and select Save Figure 15 2 Name the file and click the Save button Figure 16 Figure 15 ...

Страница 10: ...d the LED stays on 4 Press 0 5 Enter the NEW combination 6 Re enter the NEW combination to confirm The lock is now active and the configuration is frozen NOTE To change the settings after the configuration has been frozen the lock must first be reset Refer to the Reset Lock section of this document 8 Test unit operation several times before closing the door NOTE If default combinations are used it...

Страница 11: ...combination and hold down last digit of combination until lock double signals twice and the LED stays on 2 PRESS 8 3 Enter 0 this maintains current combination length value 4 Enter desired Lock Mode configuration from the chart below 5 Enter 0 and re enter the desired Lock Mode configuration to confirm NOTE Dual Mode cannot be selected if at least one additional User has not been enrolled User 9 m...

Страница 12: ...s on 2 Press 0 3 Enter your NEW combination 4 Re enter your NEW combination to confirm 5 The lock is now active and the configuration is frozen 6 Test lock operation several times before closing the door NOTE If default combinations are used it is recommended that they be changed New combination will not be accepted if it varies from the current combination by only one digit When selecting a combi...

Отзывы: