Installation
Technical Manual
37
HAC Standard fixing - 02/2018
dormakaba c-lever pro
4.12
Installing the internal fitting
NOTICE
Danger of damage to electronic components from electrostatic discharge.
If electronic printed circuit boards and components are handled incorrectly, damage may oc-
cur which leads to their complete breakdown or sporadic faults.
•
When installing and repairing the product, the general ESD protective measures are to be
observed.
NOTICE
There is a risk of crushing or shearing injuries from cables as a result of improper installation
or routing.
Ensure that the cables are routed in such a way that there is no risk of crushing or shearing in-
juries.
4.12.1
c-lever standard variant
Prerequisites
•
The drill holes are present
•
The external fitting has been placed on the door
•
The antenna cable has been guided to the inside of the door
•
The mortise lock is installed
•
With locking cylinder: The locking cylinder is inserted into the mortise lock and the forend
locking stud is screwed in but has not yet been fully tightened.
Procedure
•
Guide the antenna cable through the internal fitting (1).
1.
2.
•
Place the internal fitting onto the spindle (and the locking cylinder) (2).
•
Place the special washers onto the screws.
•
Align the external fitting and screw it in place (maximum torque: 2.5±0.5 Nm).