background image

C.

N.C.

N.O.

NC

NO

NO

NC

N.C.

N.O.

C.

N.O.

C.

N.C.

NO

NC

N.C.

N.O.

C.

NO

NC

N.C.

N.O.

C.

110 LCM WIRING DIAGRAM

SOLENOID

*

BLUE

BLACK

RED

YELLO

W

Lock Cam

Monitor Switch

(Short Arm)

TERMINAL

STRIP

Y   *

R   B

R   G

CONTROL

POWER

+    -

+   -   G

INDICATION

  POWER

Typical Control

Schematic for

Reference Only

PUSH

BUTTON

9 3

6

4

1

*

7 5

8

1

4

Y   *

R   B

BROWN

ORANGE

YELLO

W

PURPL

E

SOLENOID

Lock Bolt

Monitor Switch

+    -

+   -   G

CONTROL

POWER

INDICATION

  POWER

110 LBM WIRING DIAGRAM

R   G

Typical Control

Schematic for

Reference Only

PUSH

BUTTON

TERMINAL

STRIP

AUXILIARY

SWITCH

(LBM)

PURPLE

ORANGE

BROWN

*

9 3

6

1

4

Y   *

R   B

BLACK

RED

YELLO

W

BLUE

SOLENOID

Lock Cam Bolt

Monitor Switch

(Long Arm)

+    -

+   -   G

CONTROL

POWER

INDICATION

  POWER

110 LCBMA WIRING DIAGRAM

R   G

Typical Control

Schematic for

Reference Only

PUSH

BUTTON

TERMINAL

STRIP

PUSH

BUTTON

Typical Control

Schematic for

Reference Only

R   G

TERMINAL

STRIP

INDICATION

  POWER

CONTROL

POWER

Y   *

R   B

+    -

+   -   G

Lock Cam Bolt

Monitor Switch

(Long Arm)

SOLENOID

4

1

6

3

9

110 LCBM WIRING DIAGRAM

*

BLUE

YELLO

W

RED

BLACK

08101631

5 of 7

05/09

INS NO.

PAGE

Rev.

Содержание ES 110-4 Series

Страница 1: ...for use in fire rated doors can only be operated by momentary contact switching energized only when the push button is held depressed and cannot be held in the unlocked position 2 FAIL SAFE When powe...

Страница 2: ...heck for proper voltage being supplied to the strike Check all wiring Check the coil resistance of the solenoid and compare it to the chart located on the wiring diagram to ensure the correct solenoid...

Страница 3: ...24 x 3 8 HEX WASHER HEAD CAP SCS 2 Remove the upper cover held on by two 2 4 40 x 3 16 PHMS Removal of the upper cover should be done slowly because the locking cam spring may snap out of place Also...

Страница 4: ...PIN LOCATION IN FIELD RECEPTACLE Door shown closed and locked GREEN LIGHT CLOSED LOCKED RED LIGHT OPEN UNLOCKED G CONTROLS SHOWN FOR REFERENCE ONLY R Door shown closed and locked Dead Bolt extended in...

Страница 5: ...IRING DIAGRAM R G Typical Control Schematic for Reference Only PUSH BUTTON TERMINAL STRIP AUXILIARY SWITCH LBM PURPLE ORANGE BROWN 9 3 6 1 4 Y R B BLACK RED YELLOW BLUE SOLENOID Lock Cam Bolt Monitor...

Страница 6: ...TRIKE PREP LOCATION Measure distance from the mounting surface to tip of bolt This is DIM X DIM Y DIM X 3 32 2mm DIM Y is from edge of stop to centerline of prep Calculation assumes 3 32 2mm thick sil...

Страница 7: ...ILL VARY PER FEATURES OF STRIKE 2 CUT OFF ALL EXCESS WIRE NOT REQD FOR INSTALLATION 3 WIRES TO BE RUN FROM SIDE REAR OF STRIKE TO CONDUIT CONNECTION 4 ALL WIRING CONNECTIONS TO BE MADE AT THIS END OF...

Отзывы: