DORMA
ED400 In Floor
Controller Manual
13
DORMA AUTOMATICS, Inc.
924
Sherwood
Drive
Toll-Free:
877-367-6211
DL3128-010
Lake
Bluff,
IL
60044
Fax:
877-423-7999
10/1/2007
E-mail:
Subject to change without notice
Back-Stop menu
This menu displays and lets you set the Electrical Back-Stop angle (in °). During a Power Opening, this is where the door
stops. This should be less than the mechanical Back-Stop (which may be set by the operator, or by where the door would
encounter a physical stop). You can use it in 2 ways:
o
Before a full learn, use it to tell the controller at what angle you'll stop the door.
o
Use it to change the opening angle. (Hint: put the Program Switch in "Hold-Open" and change the setting,
while watching the door follow your setting. You can do this any time the Learn State is "Ready", even
during a learn cycle.) If you change this, you must do a cycle learn afterwards.
Close Delay menu
This menu displays and lets you set the minimumtime that the door stays at Back-Stop during a Power Opening cycle (in °)
(a.k.a.: "Hold-Open Time"). This is also the minimum time that the opener assist the user during an assist opening cycle. In
Low Energy openers, you may need to extend this time to meet A.N.S.I. specs. This is
not
the time that the door stops after
a presence or an obstacle: that's the Obstacle delay. If you change this, you must do just a cycle learn afterwards.
Close Speed menu
This menu displays and lets you set the maximum closing speed of the door, down to Latch-Check (in °/s). This is applicable
regardless of how the door was opened (manually, or automatically). Use this adjustment to ensure that the closing time to
Latch-Check is lower than what A.N.S.I. specifies (lower values in Low Energy openers). If you change this, you must do
just a cycle learn afterwards.
Latch-Check menu
This menu displays and lets you set the Latch-Check angle (in °). While closing, below this angle the door will slow down.
This is applicable regardless of how the door was opened (manually, or automatically). If you change this, you must do just a
cycle learn afterwards.
Misc. Adjustments menus
These 2 menus work together to handle many minorsettings. The first one is used to select an item, and the second one to
display its value and to adjust it.
Misc. submenu item
Function of
Display
Units,
"Dial"
knob
notes
- Power
Hold increment/decrement
"OFF": passive; or motor current
A
that
holds
door
closed
- Push-&-Go
Turn feature On or Off
"nO"; normal "yES": pressing on
-
door
starts
a
cycle
- Open
increment/decrement
If actual current > expected current
A
Obstacle
by
this
amount:
opening
obstacle
- Close
increment/decrement
If actual current < expected current
A
Obstacle
by
this
amount:
closing
obstacle
- Wall Mask
increment/decrement
Door angle beyond which the swing
°
side
sensor
is
ignored
- Lock open
increment/decrement
"OFF": normal,or delay before
s
delay
opening
- Occupied
increment/decrement
Delay after obstacle or after the area
s
delay
clears before moving again
°/s^2
- Deceleration increment/decrement
Deceleration after Back-Check
- Power Close Turn feature On or Off
“nO” or “yES”
-
Engaged
“nO” is default after reset
- Power Close increment/decrement
OFF, 1-30 degrees
-
Anlge
“20 degrees” is default after reset
- Power Close increment/decrement
00.1-10 seconds
-
Time Delay
“4 seconds” is default after reset
- Power Close increment/decrement
OFF, 0.01-1.00 Amps
-
Current
“1.00 Amps” is default after reset
- Power Boost increment/decrement
OFF, or 0.01-1.00 Amps
-
“0.50
Amps”
is
default
after
reset
- Reset /
Reset the controller /
"nO": normal
-
restore
Restore factory defaults
"yES": restore factory defaults