background image

DORMA HÜPPE

7

COMFORTDRIVE  ORIGINAL OPERATING INSTRUCTION MANUAL

 TROUBLESHOOTING USING THE FAULT CODE

With some fault codes, you can find out the 
cause yourself. Below you will see a table of 
certain fault codes with the associated 
troubleshooting remedies. If the fault code 
indicated on the push button panel is not 
listed, or the remedy indicated does not have 

the desired effect, please call our Customer 
Services. They will be able to carry out a 
detailed fault analysis on the basis of the 
fault code and initiate the necessary 
remedial activities. 

The fault code consists of a six-digit 
numerical sequence which is repeatedly 
displayed after a 5-second pause.  
The fault code is divided into two groups  
of three digits:

 

1 2 3 4 5 6

Fault code: 

X X X Y Y Y

 

 

 

Error code  

Component code

Fault code

Cause

Remedy

111

EMERGENCY STOP push button activated

Release the EMERGENCY STOP push button

131 
143, 144, 145, 
151, 152, 153, 
154, 155, 211, 
212, 213

Hardware defect

Operate the STOP push button to cancel the fault. If this does 
not have the desired effect, shut down the ComfortDrive 
partition control unit for 15 seconds. This work should only be 
done by an electrician or in-house technician.

243

Element obstructed

Use the component code to determine the element number  
(see below) and remove the obstruction from the travel path of 
that element.

244

Element positioning error

Open the partition by hand (see "Operating the partition in  
fault mode") and then press the OPEN push button in order to 
initialize the partition.

311, 433

An operable pass door is open

Close the operable pass door.

434

Extension of telescopic element (TE, only 
available with MOVEO and VERIFLEX) impeded 
by an obstruction

Remove the obstruction.

455

Stationary glass door (FTE) locked or bolted

Unlock and unbolt the stationary glass door (FTE).

Component code YYY = Element number NN

Control unit

111 (exception: this component code means a control unit fault)

Elements

112=01

113=02

114=03

115=04

121=05

122=06

123=07

124=08

Elements

125=09

131=10

132=11

133=12

134=13

135=14

141=15

142=16

Elements

143=17

144=18

145=19

151=20

152=21

153=22

154=23

155=24

Elements

211=25

212=26

213=27

214=28

215=29

221=30

222= All elements

Содержание COMFORTDRIVE HSW

Страница 1: ...Original Operating Instruction Manual Fully Automatic Operator for Movable Walls Operable Partitions COMFORTDRIVE...

Страница 2: ...2 DORMA H PPE COMFORTDRIVE ORIGINAL OPERATING INSTRUCTION MANUAL...

Страница 3: ...be read through so as to better ensure safe usage If a defective power supply cable is discovered the entire power supply unit involved must be replaced with an original spare The power supply system...

Страница 4: ...he partition is brought to a complete standstill After the obstruction has been removed the partition can be restarted in either direction by pressing OPEN or CLOSE OPERATIONAL CONTROL The partition i...

Страница 5: ...separate document Partition stop STOP push button Partition open OPEN push button Partition close CLOSE button Additional function POS1 button configured as required Additional function POS2 button co...

Страница 6: ...he fault code is repeated constantly at 5 second intervals The following illustration shows how the fault code 243121 is indicated Fault code 243121 means Obstruction Element 5 FAULT DISPLAY IN THE EV...

Страница 7: ...ancel the fault If this does not have the desired effect shut down the ComfortDrive partition control unit for 15 seconds This work should only be done by an electrician or in house technician 243 Ele...

Страница 8: ...as you would a swing door In the case of an electrically operated single action door if provided simply disengage the lock using the security key provided and open the door manually Move the elements...

Страница 9: ...in position Closing an open partition by hand Pull the elements at low speed from the stacking area to their end positions Carefully press each element against the preceding element In the case of pa...

Страница 10: ...push the elements VE DT and TE at low speed from their end positions to the stacking area Emergency operating points for the VE and TE elements manual opening Sequence for manual operation of the exte...

Страница 11: ...sk of door leaf catching on the floor 1 First open the leaf 90 2 Then release the sealing feet of the two door posts The entry holes 1 2 for the emergency crank are located in the frame area approx 60...

Страница 12: ...sliding elements VE and the pass door elements DT and also the stroke unit of telescopic element TE can be secured in place using the crank Emergency operating points for the VE and TE elements manual...

Страница 13: ...letely engage the sealing bars of that next element so that the DT does not move laterally during the closing procedure If there is no element behind the DT secure the DT element in some other way to...

Страница 14: ...ments VE and the pass door elements DT and also the stroke unit of the telescopic element TE all need to be released using the hand crank Thereafter push the elements VE DT and TE at low speed from th...

Страница 15: ...ts for TE open Sequence of manual operation of the sealing bars TE open 1 Release sealing bars top and bottom 1 direction of rotation as per label 2 Release stroke unit horizontally 2 CW CW Rotate in...

Страница 16: ...d moved into their end positions ensuring that they are gently pressed against the preceding element Thereafter the sealing bars of the standard sliding elements VE and the pass door elements DT and a...

Страница 17: ...ng points for TE close Sequence for manual operation of the sealing bars TE close 1 Engage stroke unit 2 CCW 2 Engage sealing bars top and bottom 1 direction of rotation as per label Rotate in clockwi...

Страница 18: ...ll automatically switch to the STOP mode allowing it to be operated using the push button controls as per the description starting on page 4 To bridge power supply failures DORMA H ppe Raumtrennsystem...

Страница 19: ...eight 500 kg Radius directional change 150 mm Hold open time personnel opening adjustable Travel speed Dyn up to max 250 mm s weight dependent Force limitation point 150 N Power consumption in stand b...

Страница 20: ...hueppe at DORMA H ppe Raumtrennsysteme GmbH co KG industriestra e 5 26655 OcHOlt GERMAny Phone 49 4409 666 0 Fax 49 4409 666 489 info hueppe dorma com www dorma hueppe com DORMA cBP schweiz AG Martin...

Отзывы: