Installation
26
Instruction manual DR-RS
3
is
3.6.6
Condensation drainage
Fit a small drainpipe with fall to the appropriate connection for condensation
drainage at the rear of the water heater and connect this further to the water
drainage pipe.
c
Note
All piping behind the siphon must be condensation-resistant.
3.7
Water connections,
Vented
3.7.1
Cold water side
.
1. Fit an approved stop valve
on the cold water side between the water
and the water heater, as required by regulations. Refer also to
paragraph
.
3.7.2
Top to bottom recirculating pump
You can connect a top to bottom recirculation pump to prevent stratification of
the water in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve
and a top to bottom recirculation
pump
2. Fit non-return valve
3. Fit stop valves
3.7.3
Hot water side
.
n
Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Fit the safety valve
2. Optional: fit a temperature gauge
to be able to check the temperature of
the tap water.
in the hot water outlet pipe, for use when servicing.
4. If a circulation pipe is to be fitted, then refer to paragraph
.
3.7.4
Circulation pipe
.
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump
of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve
a downstream the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves
4. Connect the circulation pipe to the T-piece on the drain valve
.