Water connections, Unvented
Instruction manual DR-RS
25
is
3.6
Water connections,
Unvented
3.6.1
Cold water side
See
1. Fit an approved stop valve
on the cold water side as required by
regulations.
Refer also to paragraph
2. Fit an approved pressure-reducing valve
.
.
4. Fit an expension valve
and connect the discharge to a drain via tundish.
3.6.2
Top to bottom recirculating pump
You can connect a top to bottom recirculation pump to prevent stratification of
the water in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve
and a top to bottom recirculation
pump
.
2. Fit non-return valve
.
3. Fit stop valves
.
3.6.3
Hot water side
See
n
Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Optional: Fit a temperature gauge
to be able to check the temperature of
the tap water.
2. Fit the T&P valve
3. Fit a stop valve
in the hot water outlet pipe, for use when servicing.
3.6.4
Drain valve
1. Fit the standard drain valve supplied
.
2. If a circulation pipe is to be fitted, then refer to paragraph
. Otherwise,
fit the sealing nut and gasket supplied with the drain valve. See
3.6.5
Circulation pipe
See
and
.
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump
of the correct capacity for the length and resistance
of the circulation system.
behind the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves
4. Connect the circulation pipe to the T-piece on the drain valve
. See
Figure 3.4
Drain valve
IMD-0122