DPM-OTR
Version 1
2019-01-28
14
F.
HIGH PRESSURE ALARM PROGRAMMING
NOTE: To enter into the High Pressure Alarm
Programming Mode from the Normal Operation screen,
press and hold the “P” button for 5 seconds until the
“PROGRAM” screen is displayed. Then press the “P”
button five times to access the High Pressure Alarm
Programming Mode (See Figure 2-23).
The High Pressure Alarm Programming mode allows the user to enable (Figure 2-24) or
disable (Figure 2-23) the high pressure alarm. A high pressure alarm will occur when a
pressure is recorded at 25% higher than the baseline pressure setting. High temperatures
can cause elevated pressures. This alarm can provide early detection of a possible
temperature issue. Use the “Left” and “Right” arrows to enable or disable the high
pressure alarm. Press and hold the “S” button until the screen flashes and audible beeps
are heard.
G.
BAUD RATE SELECTION (J1939 PRODUCTS ONLY)
NOTE: To enter into the Baud Rate Selection Mode from the Normal Operation screen,
press and hold the “P” button for 5 seconds until the “PROGRAM” screen is displayed.
Then press the “P” button six times to access the Baud Rate Selection Mode (See Figure
2-25).
The Baud Rate Selection mode allows the user to select a
250k or 500k baud rate for J1939 products. It is very
important that the selected baud rate matches the vehicle’s
baud rate. Failure to do so could cause operational issues
with the vehicle. Use the “Left” and “Right” arrows to select
the b25 for 250k (Figure 2-25) or b50 for 500k (Figure 2-26).
Press and hold the “S” button until the screen flashes and
audible beeps are heard.
Figure 2-23
Figure 2-24
Figure 2-25
Figure 2-26