18
IQ Vitals protocol (
IV
)
Fairbanks TeleWeigh (9600,7,ODD,2)
Command (RXD)
Computer to Scale
Scale Output
Responds (TXD)
Scale to Computer
Description
Z or z
Zero the scale (if in motion, scale will wait until
stable, then zero)
<cr> or W
<weight><sp><uu><sp>
<mot><sp><sp><cr><lf>
<eot>
Current Display Weight. Active, Stable Hold, or
Average Hold.
( <mot> GR = stable, gr = motion )
U
Scale scrolls through available weight units.
H
<height><sp><hh><sp>GR<sp>
<sp><cr><lf>
Current height value in inches “in”.
R or r
Scale performs a Reweigh operation (same as
pressing the Reweigh button)
Welch Allyn Spot protocol (
VU
)
(2400,7,EVEN,1)
Command (RXD)
Computer to Scale
Scale Output
Responds (TXD)
Scale to Computer
Description
DR<cr><lf>
<mot><sp><sp>
<weight><uu><cr><lf>
Current Weight.
( <mot> SD = stable, S_ = motion )
Doran F0 protocol (
f0
)
(9600,8,NO,1)
Command (RXD)
Computer to Scale
Scale Output
Responds (TXD)
Scale to Computer
Description
Z or z
Zero the scale (if in motion, scale will wait until
stable, then zero)
<cr> or W
<stx><pol><weight><sp>
<uu><sp><cr><lf>
Current Display Weight. Active, Stable Hold, or
Average Hold.
U
Scale scrolls through available weight units.
H
<height><sp><hh><sp>GR
<sp><cr><lf>
Current Height value in inches or centimeters.
R or r
Scale performs a Reweigh operation (same as
pressing the Reweigh button)