Electrical System
Page 67
SP000935
Operation
1.
Digging Mode
This mode is used for general digging work, loading work
and ground leveling work requiring quick stops. The current
to the solenoid valve for swing priority is shut off.
2.
Trenching Mode
This mode is used for heavy duty ditch digging work or for
loading work requiring big swing angles. The voltage is
assigned to the swing priority control valve activating the
swing control valve restricting the flow of oil to the boom
and the arm.
ARO0270L
Figure 57