The power mode switch permits the selection of the appropriate
engine power depending on the working condition. One of the
two, Power Mode or Standard Mode, setting can be selected.
When the engine starter switch is turned "ON," the power mode
is automatically defaulted to standard mode. The desired mode
can be selected by pressing the selector button on the
instrument panel. When the power mode is selected, the
indicator light will turn "ON" to display the selected mode.
The quantity of oil discharged by the pump and the engine
speed are determined by the mode selected by the operator.
The pump output in each mode is determined by the mode
selection and is listed in the following table