MAINTENANCE
Operating & Maintenance Manual
45
Air Cleaner
If this unit is equipped with the Optional Full Instrumentation, the SECU Module, located inside
front panel near instrument panel, will Display #9 when either engine or compressor air filter
is restricted.
Weekly squeeze the rubber valve (precleaner dirt dump) on each air cleaner housing to ensure
that they are not clogged.
The air filters restricted sensor will automatically reset after the main power switch is turned to
“OFF.”
To service the air cleaners on all units proceed as follows:
1. Loosen the 3 latches on the sides of the air cleaner cover.
2. Remove air cleaner body.
3. Pull out air cleaner element.
4. Pull out safety element if installed.
5. Install new filters in air cleaner body.
6. Re-install cover on air cleaner body.
7. Close the 3 latches after securing to air cleaner body.
In addition, the air cleaner system (housing and piping) should be inspected every month for
any leakage paths or inlet obstructions. Make sure the air cleaner mounting bolts and clamps
are tight. Check the air cleaner housing for dents or damage which could lead to a leak. Inspect
the air transfer tubing from the air cleaner to the compressor and the engine for leaks.
Make sure that all clamps and flange joints are tight.
Make sure the pre-cleaner dirt dump is pointed within 30° of down.
Gauges
The instruments or gauges are essential for safety, maximum productivity and long service life
of the machine. Inspect the gauges and test any diagnostic lamps prior to start-up. During
operation observe the gauges and any lamps for proper functioning. Refer to Operating
Controls, for the normal readings.
Fuel Tank
CLEAN fuel in the fuel tanks is vitally important and every precaution should be taken to
ensure that only clean fuel is poured or pumped into the tank.
When filling the fuel tank on this unit, by methods other than a pump and hose, use a CLEAN
non-metallic funnel.
Battery
Keep the battery posts-to-cable connections clean, tight and lightly coated with a grease. Also
the electrolyte level in each cell should cover the top of the plates. If necessary, top-up with
clean distilled water.
Содержание D82
Страница 2: ...2...
Страница 5: ...3 FOREWORD...
Страница 8: ...Operation Maintenance Manual FOREWORD 6...
Страница 9: ...7 DRAWBAR NOTICE...
Страница 11: ...DRAWBAR NOTICE Operating Maintenance Manual 9...
Страница 12: ...Operating Maintenance Manual DRAWBAR NOTICE 10...
Страница 13: ...11 SAFETY...
Страница 16: ...Operating Maintenance Manual SAFETY 14...
Страница 18: ...Operating Maintenance Manual SAFETY 16...
Страница 19: ...SAFETY Operating Maintenance Manual 17...
Страница 21: ...SAFETY Operating Maintenance Manual 19...
Страница 23: ...21 NOISE EMISSION...
Страница 29: ...27 GENERAL DATA...
Страница 32: ...Operating Maintenance Manual GENERAL DATA 30...
Страница 33: ...31 OPERATION...
Страница 43: ...41 LUBRICATION...
Страница 45: ...43 MAINTENANCE...
Страница 55: ...53 TROUBLESHOOTING...