Operating & Maintenance Manual
OPERATION
36
Starting
• Turn the POWER switch to “ON”.
• Turn Power switch to “START” position to crank engine. Hold switch in “START”
position for approximately 5 seconds after engine starts.
NOTICE
Do not operate the starter motor for more than 30 seconds without allowing at
least 30 seconds cooling time between start attempts.
Release Power Switch (it will automatically move to the “ON” position) when the engine starts
and sustains running.
• Allow engine to warm up 5 to 10 minutes.
• Press the “Service Air Button”. Open air service valve(s).
Cold Weather Starting
• Turn power switch to the glow plug position and hold 10 seconds. Then turn to start.
NOTICE
Exercise extreme caution when using a booster battery to start. To jump start:
Connect the ends of one booster cable to the positive (+) terminals of each
battery. Then connect one end of the other cable to the negative (-) terminal of
the booster battery and the other end to the engine block. Not to the negative (-
) terminal of the weak battery.
NOTICE
Do NOT use ETHER !
Содержание D82
Страница 2: ...2...
Страница 5: ...3 FOREWORD...
Страница 8: ...Operation Maintenance Manual FOREWORD 6...
Страница 9: ...7 DRAWBAR NOTICE...
Страница 11: ...DRAWBAR NOTICE Operating Maintenance Manual 9...
Страница 12: ...Operating Maintenance Manual DRAWBAR NOTICE 10...
Страница 13: ...11 SAFETY...
Страница 16: ...Operating Maintenance Manual SAFETY 14...
Страница 18: ...Operating Maintenance Manual SAFETY 16...
Страница 19: ...SAFETY Operating Maintenance Manual 17...
Страница 21: ...SAFETY Operating Maintenance Manual 19...
Страница 23: ...21 NOISE EMISSION...
Страница 29: ...27 GENERAL DATA...
Страница 32: ...Operating Maintenance Manual GENERAL DATA 30...
Страница 33: ...31 OPERATION...
Страница 43: ...41 LUBRICATION...
Страница 45: ...43 MAINTENANCE...
Страница 55: ...53 TROUBLESHOOTING...