- 18 -
Fuel Oil Selection Chart
#) Not specified In ASTM D 975
+) Differs from ASTM D 975
NOTE :
1. The cloud point should be 6
˚C
(10
˚F
) below the lowest expected fuel temperature to
prevent clogging of fuel fitters by crystals.
General Fuel
ASTM
No. 1
No. 2
DIN 51601
Classification
Test
ASTM 1-D
ASTM 2-D
Gravity,
˚
API #)
D 287
40 ~ 44
33 ~ 37
0.815 ~ 0.855
Flash Point
D 93
100 (38)
125 (52)
131 (55)
Min.
˚F (˚C
)
Viscosity, Kinematic
D 445
1.3 ~ 2.4
1.9 ~ 4.1
1.8 ~ 10
CST 100
˚F
(40
˚C
)
Cloud Point
˚F
#)
D 2500
See Note 1)
See Note 1)
See Note 1)
Sulfur Content
D 129
0.5
0.5
0.15
wt%, Max.
Carbon Residue
D 524
0.15
0.35
0.1
on 10%, wt%, Max.
Accelerated Stability
D 2274
1.5
1.5
Total Insolubles
mg/100 ml, Max. #)
Ash, wt%, Max.
D 482
0.01
0.01
Cetane Number, Min. +)
D 613
45
45
> 45
Distillation
D 86
Temperature,
˚F (˚C
)
IMP, Typican #)
350(177)
375(191)
10% Typical #)
385(196)
430(221)
50% Typical #)
45(218)
510(256)
680(360)
90% +)
500 (260) Max.
625(329) Max.
End Point #)
550(288) Max.
675(357) Max.
Water & Sediment
D 1796
0.05
0.05
0.05
%, Max.
Содержание D1146
Страница 1: ......
Страница 57: ...7 2 Trouble Shooting 53 ...
Страница 58: ... 54 ...
Страница 59: ... 55 ...
Страница 60: ... 56 ...
Страница 61: ... 57 ...
Страница 62: ... 58 ...
Страница 63: ... 59 ...
Страница 134: ... 7 Governor adjustment D1146 130 EA9M4002 0 Injection Pump Speed rpm Rack Position mm 2 4 6 8 10 12 14 C D B A ...
Страница 136: ... 7 Governor adjustment D1146T 132 EA9M4002 0 Injection Pump Speed rpm Rack Position mm 2 4 6 8 10 12 14 C D B A ...